English
Language : 

SC4201_04 Datasheet, PDF (2/12 Pages) Semtech Corporation – Multi-Phase Link Controller
SC4201
POWER MANAGEMENT
Absolute Maximum Ratings
Exceeding the specifications below may result in permanent damage to the device, or device malfunction. Operation outside of the parameters
specified in the Electrical Characteristics section is not implied.
Parameter
Symbol
Limits
Units
Supply Voltage
RT, SYNC
Operating Ambient Temperature Range
Junction Temperature Range
Storage Temperature Range
Lead Temperature (Soldering) 10 sec
Thermal Impedance Junction to Ambient
ESD Rating (Human Body Model)
VIN
VP_K
TA
TJ
TSTG
TLEAD
θJA
ESD
7
-0.3V to VDD +0.3
-40 to +125
-40 to 150
-65 to 150
+300
206
2
V
V
°C
°C
°C
°C
°C/W
kV
Electrical Characteristics
Unless
specified:
TA
=
T
I
=
-40
to
+125°C,
V
DD
=
5V,
R
T
=
100K,
4-phase.
Parameter
Symbol
Conditions
Min Typ Max Units
Supply Voltage, Operating
Supply Current
VDD Start Threshold
VDD
3.0
6.0
V
IDD
VDD = 6V, RT = 36.5kΩ , COUT = 20pF
2.35 2.60 mA
3.10
V
VDD UVLO Hysteresis
70 100 130 mV
Output Frequency, per phase
FOUT
Output Frequency Stability
Phase Accuracy
See graphs, Fig 2 - 5
0.1
VDD = 3V to 6V
By design, not tested
2
MHz
10
%
1
%
Sync Input Threshold
O/P Rise Time
O/P Fall Time
Output Voltage
Output Current (peak)
VSYNC
TR
TF
VOUT
IOUT
See pin description
COUT = 20pF, VDD = 3V to 6V
COUT = 20pF, VDD = 3V to 6V
VDD = 5V
VDD = 3.3V
VDD/3
V
10
ns
10
ns
VDD
V
25
mA
10
Output Impedance
ROUT
Output Duration
TP
Note:
60
Ω
(1)
ns
(1)
TP
=
TOUT
N
where
TOUT
=
output
signal
period
of
individual
phase.
N = 3 for 3 phase operation, N = 4 for 2/4 phase operation.
 2004 Semtech Corp.
2