Register and Bit Definitions (continued)
BL[4:0]
These bits are used to set the current for the backlight
current sinks. All enabled backlight current sinks will sink
the same current, as shown in Table 1.
Table 1 — Backlight Current Control Bits
BL_4 BL_3 BL_2 BL_1 BL_0
Backlight Current
(mA)
0
0
0
0
0
0.5
0
0
0
0
1
1.0
0
0
0
1
0
1.5
0
0
0
1
1
2.0
0
0
1
0
0
2.5
0
0
1
0
1
3.0
0
0
1
1
0
3.5
0
0
1
1
1
4.0
0
1
0
0
0
4.5
0
1
0
0
1
5
0
1
0
1
0
5.5
0
1
0
1
1
6
0
1
1
0
0
6.5
0
1
1
0
1
7
0
1
1
1
0
7.5
0
1
1
1
1
8
1
0
0
0
0
8.5
1
0
0
0
1
9
1
0
0
1
0
9.5
1
0
0
1
1
10
1
0
1
0
0
10.5
1
0
1
0
1
11
1
0
1
1
0
11.5
1
0
1
1
1
12
1
1
0
0
0
13
1
1
0
0
1
14
1
1
0
1
0
15
1
1
0
1
1
17
1
1
1
0
0
19
1
1
1
0
1
21
1
1
1
1
0
23
1
1
1
1
1
25
BL Enable Control Register (0x01)
This register is used to enable the backlight current
sinks.
BLEN[4:1]
These bits are used to enable current sinks (active high,
default low).
BLEN_4 — Enable bit for backlight BL4
BLEN_3 — Enable bit for backlight BL3
BLEN_2 — Enable bit for backlight BL2
BLEN_1 — Enable bit for backlight BL1
When enabled, the current sinks will carry the current set
by the backlight current control bits BL[4:0], as shown in
Table 1.