English
Language : 

SC622A Datasheet, PDF (18/23 Pages) Semtech Corporation – LED Light Management Unit Charge Pump, 400mA Flash LED, Dual LDOs, and I2C Interface
SC622A
Register Map
Address
D7
D6
0x02
0(1)
0(1)
D5
D4
D3
D2
D1
D0
Reset
Value
Description
Flash/Spotlight
0(1)
FLTO
FL_2
FL_1
FL_0 FL/SPLB 0x10
Control
0x03
0(1)
LDO2_2 LDO2_1 LDO2_0 LDO1_3 LDO1_2 LDO1_1 LDO1_0 0x00
LDO Control
Notes:
(1) 0 = always write a 0 to these bits
Register and Bit Definitions
Flash/Spotlight Control Register (0x02)
This register is used to configure the flash time-out
feature, the flash or spotlight current, and select flash or
spotlight current ranges.
Table 1 — Flash/Spotlight Control Bits
FL_2 FL_1 FL_0
FL/
SPLB
Flash/Spotlight
Current (mA)
0
0
0
0
OFF
FLTO
0
0
1
0
50
This bit is used to enable the flash safety time-out feature.
0
1
0
0
100
The default state is enabled with FLTO = 1. If this bit is set,
the device will turn off the flash after a nominal period of
0
1
1
0
150
1s. Two ways to re-enable the flash function after a safety
1
0
0
0
200
time-out are:
• Pull the FLEN pin low to re-enable the flash
1
0
1
0
250
function
• Clear and re-write FL[2:0]
1
1
0
0
250
1
1
1
0
250
FL[2:0]
0
0
0
1
OFF
These bits are used to set the current for the flash current
0
0
1
1
300(1)
sink when configured for flash or spotlight by the FL/
0
1
0
1
350(1)
SPLB bit. Bits FL[2:0] set the flash or spotlight current, as
shown in Table 1.
0
1
1
1
400(1)
1
0
0
1
400(1)
1
0
1
1
400(1)
1
1
0
1
400(1)
1
1
1
1
400(1)
Note:
(1) When on continuously, the device may reach the temperature
limit with 300mA and higher.
18