Reset High Register (RESET_H)
Address:
0x07
Reset value: 0x00
7
6
5
4
3
2
1
0
RESET_KEY_H[7:0]
w
w
w
w
w
w
w
w
Bits 7:0 RESET_KEY_H[7:0]: Reset Key
0xAA: generate a system reset. Both the RESET_L and the RESET_H registers have to
be written with the correct key to generate a reset.
Any other value: a system reset is not generated.
Main Status Register (STATUS)
Address:
0x08
Reset value: 0xC0
7
6
CTS
CTS_API
rw
rw
5
4
Res
3
STATUS3
rw
2
STATUS2
rw
1
STATUS1
rw
0
STATUS0
rw
Bit 7 CTS: Clear To Send
This bit indicates if a new command can be issued to the controller.
0: The controller is busy processing a previous command. New commands should
not be sent to the controller.
1: The controller can accept a new command over the communication interface.
Bit 6 CTS_API: Clear to Send for API
This bit indicates if a new API call can be issued to the controller.
0: The controller is busy processing a previous API call. New API calls should not be
sent to the controller.
1: The controller can accept a new API call over the communication interface.
Bits 5:4 Reserved
Bit 3 STATUS3: STATUS3 Event Flag
0: No event is signaled in the STATUS3 register
1: An event is signaled in the STATUS3 register
Bit 2 STATUS2: STATUS2 Event Flag
0: No event is signaled in the STATUS2 register
1: An event is signaled in the STATUS2 register
Bit 1 STATUS1: STATUS1 Event Flag
0: No event is signaled in the STATUS1 register
1: An event is signaled in the STATUS1 register
Bit 0 STATUS0: STATUS0 Event Flag
0: No event is signaled in the STATUS0 register
1: An event is signaled in the STATUS0 register