English
Language : 

SEMIX503GD126HDC Datasheet, PDF (1/5 Pages) Semikron International – Trench IGBT Modules
SEMiX503GD126HDc
SEMiX® 33c
Trench IGBT Modules
SEMiX503GD126HDc
Features
• Homogeneous Si
• Trench = Trenchgate technology
• VCE(sat) with positive temperature
coefficient
• High short circuit capability
• UL recognised file no. E63532
Typical Applications*
• AC inverter drives
• UPS
• Electronic Welding
Remarks
• Case temperatur limited to TC=125°C
max.
• Not for new design
Absolute Maximum Ratings
Symbol Conditions
IGBT
VCES
IC
Tj = 150 °C
Tc = 25 °C
Tc = 80 °C
ICnom
ICRM
VGES
tpsc
Tj
ICRM = 2xICnom
VCC = 600 V
VGE ≤ 20 V
VCES ≤ 1200 V
Tj = 125 °C
Inverse diode
IF
IFnom
IFRM
IFSM
Tj
Tj = 150 °C
Tc = 25 °C
Tc = 80 °C
IFRM = 2xIFnom
tp = 10 ms, sin 180°, Tj = 25 °C
Module
It(RMS)
Tstg
Visol
AC sinus 50Hz, t = 1 min
Characteristics
Symbol Conditions
IGBT
VCE(sat)
VCE0
rCE
VGE(th)
ICES
Cies
Coes
Cres
QG
RGint
td(on)
tr
Eon
td(off)
tf
Eoff
Rth(j-c)
IC = 300 A
VGE = 15 V
chiplevel
Tj = 25 °C
Tj = 125 °C
Tj = 25 °C
Tj = 125 °C
VGE = 15 V
Tj = 25 °C
Tj = 125 °C
VGE=VCE, IC = 12 mA
VGE = 0 V
VCE = 1200 V
Tj = 25 °C
Tj = 125 °C
VCE = 25 V
VGE = 0 V
f = 1 MHz
f = 1 MHz
f = 1 MHz
VGE = - 8 V...+ 15 V
Tj = 25 °C
VCC = 600 V
IC = 300 A
Tj = 125 °C
Tj = 125 °C
RG on = 2.2 Ω
RG off = 2.2 Ω
Tj = 125 °C
Tj = 125 °C
Tj = 125 °C
Tj = 125 °C
per IGBT
Values
1200
466
327
300
600
-20 ... 20
10
-40 ... 150
412
284
300
600
2000
-40 ... 150
600
-40 ... 125
4000
Unit
V
A
A
A
A
V
µs
°C
A
A
A
A
A
°C
A
°C
V
min.
typ.
max. Unit
1.7
2.1
V
2
2.45
V
1
1.2
V
0.9
1.1
V
2.3
3.0
mΩ
3.7
4.5
mΩ
5
5.8
6.5
V
0.1
0.3
mA
mA
21.6
nF
1.13
nF
0.98
nF
2400
nC
2.50
Ω
275
ns
55
ns
28
mJ
625
ns
125
ns
44
mJ
0.08 K/W
GD
© by SEMIKRON
Rev. 17 – 16.12.2009
1