English
Language : 

L6100161 Datasheet, PDF (1/12 Pages) Semikron International – Board 4s SKYPER 32 R
Board 4s SKYPER 32 R
SKYPER®
Adaptor board
Board 4s SKYPER 32 R
Preliminary Data
Features
• Two output channels
• Failure management
Typical Applications*
• Adaptor board for SKYPER 32 IGBT
drivers in bridge circuits for industrial
applications
• DC bus up to 1200V
Footnotes
All characteristics listed in the data sheet
are guilty for the use with SKYPER 32
Please consider the derating of the ambient
temperature
Please refer to the datasheet of SKYPER
32 for further information
Absolute Maximum Ratings
Symbol Conditions
Values
Unit
Vs
Supply voltage primary
16
V
IoutPEAK Output peak current
IoutAVmax Output average current
15
A
50
mA
fmax
max. switching frequency
50
kHz
VCE
Collector emitter voltage sense across
the IGBT
1700
V
Visol IO
Isolation test voltage input - output
(AC, rms, 2s)
4000
V
VisolPD
Partial discharge extinction voltage,
rms, QPD d 10pC
1500
V
Visol12
Isolation test voltage output 1 - output
2 (AC, rms, 2s)
1500
V
RGon min
RGoff min
Minimum rating for external RGoff
1.5
:
1.5
:
Top
Operating temperature
-25 ... 85
°C
Tstg
Storage temperature
-25 ... 85
°C
Characteristics
Symbol Conditions
min.
typ.
max. Unit
Vs
Supply voltage primary side
14.4
15
15.6
V
Vj
input signal voltage on / off
15 / 0
V
VIT+
Input treshold voltage HIGH
12.3
V
VIT-
Input threshold voltage (LOW)
4.6
V
VG(on)
Turn on gate voltage output
15
V
VG(off)
Turn off gate voltage output
-7
V
td(on)IO
Input-output turn-on propagation time
1.1
µs
td(off)IO
Input-output turn-off propagation time
1.1
µs
Adaptor board
© by SEMIKRON
Derating
This is an electrostatic discharge sensitive device (ESDS), international standard IEC
60747-1, Chapter IX
* The specifications of our components may not be considered as an assurance of component
characteristics. Components have to be tested for the respective application. Adjustments
may be necessary. The use of SEMIKRON products in life support appliances and systems is
subject to prior specification and written approval by SEMIKRON. We therefore strongly
recommend prior consultation of our personal.
Rev. 1 – 21.04.2010
1