English
Language : 

SS109_14 Datasheet, PDF (3/5 Pages) SEC Electronics Inc. – Unipolar Hall Switch
SS109
Unipolar Hall Switch
General Electrical Specifications
DC Operating Parameters TA = 25℃, VDD= 3.5V to 24V (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Units
Supply Voltage
VDD
Operating
3.5
24
V
Supply Current
IDD
B < BRP
5
mA
Output Saturation Voltage
VDSon
IOUT = 20mA, B > BOP
0.5
V
Output Leakage Current
IOFF
B < BRP VOUT = 24V
1 10 µA
Output Rise Time
tr
RL = 1kΩ, CL = 20pF
0.25
µs
Output Fall Time
tf
RL = 1kΩ, CL = 20pF
0.25
µs
Maximum Switching Frequency FSW
---
10
KHz
Package Thermal Resistance
RTH
Single layer (1S) Jedec board
301
°C/W
Table 3: Electrical Specifications
Note: The output of SS109 will be switched after the supply voltage is over 2.2V, but the magnetic
characteristics won't be normal until the supply is over 3.5V.
Magnetic Specifications
DC Operating Parameters VDD = 3.5V to 24V (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Units
Operating Point
BOP
100
120
160
G
Release Point
Hysteresis
BRP
BHYST
VDD = 12V DC., TA = 25°C 50
20
85
140
G
35
50
G
Table 4: Magnetic Specifications
Output Behavior versus Magnetic Pole
DC Operating Parameters TA = -40℃ to 150℃, VDD = 3.5V to 24V (unless otherwise specified)
Parameter
Test Conditions
OUT
Nouth pole (SOT )
B > BOP
Null or weak magnetic field
B < BRP
Table5:Output behavior versus magnetic pole
Low
High
3
V2.10 May 1, 2012