English
Language : 

LT1085220M05 Datasheet, PDF (3/3 Pages) Seme LAB – LOW DROPOUT 3 AMP POSITIVE VOLTAGE REGULATOR
LT1085–220M–05
LT1085–05–220M
LT1085–12–220M
MILITARY VERSION
ELECTRICAL CHARACTERISTICS (TJ = –55 to +150°C unless otherwise stated)
Parameter
Output
Voltage Test Conditions
Min. Typ. Max.
ICL
Current Limit
IQ
Quiescent Current
VIN – VOUT = 5V
VIN – VOUT = 25V
5
VIN £ 20V
12 VIN £ 25V
TJ = –55 to 150°C 3.2
4
TJ = –55 to 150°C 0.2 0.5
TJ = –55 to 150°C
5
10
TJ = –55 to 150°C
5
10
Minimum Load Current 4
ADJ. VIN – VOUT = 25V
TJ = –55 to 150°C
5
10
REG(THERM) Thermal Regulation
TP = 30ms
TA = 25°C
0.004 0.02
RA
Ripple Rejection
5 TJ = –55 to 150°C
VIN = 8V
60
68
12 COUT = 25mF Tantalum VIN = 15V
54
60
ADJ.
f = 120Hz
IO = 3A
VIN – VOUT = 3V
CADJ = 25mF
60
75
IPIN
Adjust Pin Current
ADJ.
TJ = –55 to 150°C
55
120
DIPIN Adjust Pin Current Change
ADJ.
VIN – VOUT = 1.5 to 15V
IO = 10mA to 3A
TJ = –55 to 150°C
0.2
5
TS
Temperature Stability
TJ = –55 to 150°C
0.5
Long Term Stability
TA = 125°C
T = 1000 Hrs
0.3
1
VN
RMS Output Noise
f = 10Hz to 10kHz
TA = 25°C
0.003
RqJC Thermal Resistance
Control Circuitry
TBA
Junction – Case
Power Transistor
TBA
Unit
A
mA
%/W
dB
mA
mA
%
%
%
°C/W
Notes:
1. See thermal regulation specifications for changes in output voltage due to heating effects. Load and line regulation are
measured at a constant junction temperature by low duty cycle pulse testing. Load regulation is measured at the output
lead » 1/8” from the package.
2. Line and load regulation are guaranteed up to the maximum power dissipation of 30W. Power dissipation is determined
by the input - output differential and the output current. Guaranteed maximum power dissipation will not be available over
the full input - output voltage range.
3. Dropout voltage is specified over the full output current range of the device.
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Prelim. 10/95