LM1084HN
ELECTRICAL CHARACTERISTICS (Per Diode)
Parameter
Test Conditions
VIN - VOUT =3.0V
VREF Reference Voltage
IOUT = 10mA
TA = 25°C
1.5V £ VIN - VOUT £ 25V
•
10mA £ IOUT £ IFL
VOUT Line Regulation (Note 1)
• 1.5 £ VIN - VOUT £ 15V
IOUT = 10mA
TA = 25°C
VIN
15V £ VIN - VOUT £ 35V
IOUT =10mA
VIN - VOUT =3.0V
TA = 25°C
VOUT Load Regulation
10mA £ IOUT £ IFL
VIN
•
Min.
1.238
1.225
VDO
VIN
VOUT
Dropout Voltage
Thermal Regulation
Ripple Rejection
IAdj
Ajust Pin Current
3IAdj
IMin
ILim
VOUT
T
VOUT
T
Ajust Pin Current Change
Minimum Load Current
Current Limit
Temperature Stability (Note 2)
Long Term Stability (Note 2)
IOUT = IFL
• DVREF = 1%
30ms pulse
TA = +25°C
f = 120Hz, CAdj = 25mF
COUT = 25mF (tantalum), IFL = 3.0A • 60
VIN - VOUT =3.0V
1.5V £ VIN - VOUT £ 25V
•
10mA £ IOUT £ IFL
1.5V £ VIN - VOUT £ 25V
•
10mA £ IOUT £ IFL
VIN - VOUT = 25V
•
VIN - VOUT = 5.0V
• 5.5
VIN - VOUT = 25V
• 0.3
Tj = -55 to +125°C
•
TA = +125°C, t = 1000hrs
Typ.
Max. Unit
1.262
V
1.270
0.2
%
0.5
0.3
%
0.4
1.5
V
0.015 %W
dB
120
mA
5.0
mA
10 mA
A
1.5
%
1.0
Notes:
1 Line and Load Regulation are measured at a constant junction temperature using a low duty cycle pulse technique.
Power dissipation is internally limted. Regulation is guaranteed up to maximum power dissipation of 45 W. Power
dissipation is determined by the input/output differential voltage and the output current. Guaranteed maximum power
dissipation is not available over the full input/output voltage range.
2 Guaranteed by design, characterization or correlation to other tested parameters.
3 • Specification applies over the full operating temperature range.
4 IFL is defined as the minimum value of current limit as a function of input to output voltage.
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk