ABSOLUTE MAXIMUM RATINGS
Parameter
Supply Voltage
Differential Input Voltage
Input Voltage
Power Dissipation
Opearting, Storage Temperature
Symbol
VKA
IKA
IREF
PD
TJ, TSTG
Value
20
-10 ~ +250
-0.05 ~ +10
225
150, -65~150
Units
V
mA
mA
mW
°C
ELECTRICAL CHARACTERISTICS (VCC=5V, All voltage referenced to GND unless otherwise specified)
Parameter
Symbol
Test Conditions
Min
Typ
Max Units
Referencet Voltage TL432KC
TL432KB
TL432KA
Deviation of reference input
voltage over temperature (note 1)
Ratio of Change in reference
input voltage to the change in
cathode voltage
Reference Input Current
Deviation of reference input
current over temperature range
VREF
ΔVREF
/ΔT
ΔVREF
/ΔVKA
IREF
IREF
VKA = VREF, IK = -10mA (Fig. 1)
VKA = VREF, IK = -10mA,
Ta = Full Range (Fig. 1)
IK = -10 mA
(Fig. 2)
ΔVKA =
20V~VREF
IK = 10mA, R1 = 10K ,
R2 = (Fig.2)
IK = 10mA, R1 = 10 KW,
R2 = (Fig. 2)
1.215
1.228
1.234
1.24
3.0
-1.4
1.4
0.4
1.265
1.252
V
1.246
20
mV
mV
-2.0
/V
3.5
A
1.2
A
Minimum cathode current for
regulation
IKA(min)
VKA = VREF (Fig. 1)
0.15
0.3
mA
Off-State Cathode Current
IKA(off)
VKA = 20V, VREF = 0 (Fig.3)
0.1
1.0
A
Dynamic Output Inpedance
(note 2)
|ZkA|
VKA = VREF , IK = 1 ~ 100 mA
F 1.0 KHz (Fig. 1)
0.2
0.5
Note 1. Deviation of reference input voltage, VDEV, is defined as the maximum variatio of the reference over the full temperature range.
The average temperature coefficient of the reference input voltage α VREF is defined as:
Where:
T2-T1 = full temperature change.
α VREF can be positive or negative depending on whether the slope is positive or negative.
Note 2. The dynamic output impedance, RZ, is defined as: