English
Language : 

SUF301C_15 Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – 3.0 Amp Surface Mount Super Fast Recovery Rectifiers
Elektronische Bauelemente
SUF301C~SUF305C
Voltage 50 V ~ 600 V
3.0 Amp Surface Mount Super Fast Recovery
Rectifiers
RoHS Compliant Product
A suffix of “-C” specifies halogen & lead-free
FEATURES
 Ideal for surface mount applications
 Easy pick and place
 Built-in strain relief
 Super Fast switching speed under 35ns
MECHANICAL DATA
 Case: Molded plastic SMC
 Epoxy: UL 94V-0 rate flame retardant
 Polarity: Color band denotes cathode
 Mounting position: Any
PACKAGE INFORMATION
Package
MPQ
SMC
3K
Leader Size
13’ inch
SMC
B
A
C
H
D
GE
F
REF.
A
B
C
D
Millimeter
Min. Max.
2.750 3.250
6.520 7.110
5.590 6.220
2.000 2.620
REF.
E
F
G
H
Millimeter
Min. Max.
-
0.203
7.750 8.130
0.760 1.520
0.150 0.305
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating 25°C ambient temperature unless otherwise specified. Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameter
Symbol
SUF301C
Part Number
SUF302C SUF303C SUF304C
SUF305C
Maximum Repetitive Peak Reverse Voltage
VRRM
50
100
200
400
600
Maximum RMS Voltage
VRMS
35
70
140
280
420
Maximum DC Blocking Voltage
VDC
Maximum Average Forward Rectified
Current.375”(9.5mm) Lead Length at
IF
TA=55°C
Peak Forward Surge Current, 8.3ms single
half sine-wave superimposed on rated
IFSM
load@ TL=100°C
Maximum Instantaneous Forward Voltage
@ 3A
VF
50
100
200
400
600
3
80
0.98
1.3
1.7
Maximum DC Reverse Current TA=25°C
at Rated DC Blocking Voltage TA=100°C
IR
Maximum Reverse Recovery Time 1
TRR
Typical Junction Capacitance 2
CJ
10
500
35
50
40
Typical Thermal Resistance3
RθJL
12
RθJA
47
Operating & Storage Temperature
TJ,TSTG
Notes:
1. Reverse Recovery Time test condition:IF=0.5A, IR=1A, IRR=0.25A
2. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
3. Units Mounted on P.C.B. with 0.31*0.31’’(8*8mm) Copper Pad Areas.
-55~150
Unit
V
V
V
A
A
V
μA
nS
pF
°C/W
°C/W
°C
http://www.SeCoSGmbH.com/
29-Jul-2013 Rev.B
Any changes of specification will not be informed individually.
Page 1 of 2