English
Language : 

SUF101B Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – 1.0AMP Surface Mount Super Fast Recovery Rectifiers
SUF101B THRU SUF105B
Elektronische Bauelemente
VOLTAGE 50V ~ 600V
1.0AMP Surface Mount Super Fast Recovery Rectifiers
RoHS Compliant Product
A suffix of "-C" specifies halogen-free
FEATURES
* Ideal for surface mount applications
* Easy pick and place
* Built-in strain relief
* Super Fast switching speed under 35ns
MECHANICAL DATA
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
* Metallurgically bonded construction
* Polarity: Color band denotes cathode end
* Mounting position: Any
* Weight: 0.063 grams
DO-214AA(SMB)
.083(2.11)
.075(1.91)
.096(2.44)
.083(2.13)
.050(1.27)
.030(0.76)
.185(4.70)
.160(4.06)
.155(3.94)
.130(3.30)
.012(0.31)
.006(0.15)
.008
MAX.
(.203)
.220(5.59)
.200(5.08)
Dimens ions in inches and (millimeters )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Ta=55 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Instantaneous Forward Voltage at 1.0A
Maximum DC Reverse Current
Ta=25 C
at Rated DC Blocking Voltage
T a=100 C
Maximum Reverse Recovery Time (Note 1)
Typical Junction Capacitance (Note 2)
Thermal Resistance, Junction to Ambient (Note 3) RθJA
Operating and Storage Temperature Range TJ, TSTG
SUF101B
50
35
50
SUF102B SUF103B
100
200
70
140
100
200
SUF104B
400
280
400
SUF105B
600
420
600
UNITS
V
V
V
1.0
A
30
0.95
1.25
5.0
80
35
15
75
-65 +175
A
1.7
V
µA
µA
nS
pF
°C/W
C
NOTES:
1. Reverse Recovery Time test condition: IF=0.5A, IR=1.0A, IRR=0.25A
2. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
3. Device mounted FR-4 PCB 0.013mm
http://www.SeCoSGmbH.com
01-Jun-2002 Rev. A
Any changing of specification will not be informed individual