SUF101A_15 Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – 1.0 Amp High Efficiency Recovery Rectifiers
Elektronische Bauelemente
SUF101A~SUF105A
Voltage 50 V ~ 600 V
1.0 Amp High Efficiency Recovery Rectifiers
RoHS Compliant Product
A suffix of “-C” specifies halogen & lead-free
FEATURES
 Ideal for surface mount applications
 Easy pick and place
 Built-in strain relief
 Super Fast switching speed under 35ns
MECHANICAL DATA
 Case: Molded plastic SMA/DO-214AC
 Epoxy: UL 94V-0 rate flame retardant
 Polarity: Color band denotes cathode
 Mounting position: Any
 Weight: 0.064 gram
PACKAGE INFORMATION
Package
MPQ
SMA
5K
Leader Size
13’ inch
SMA
B
A
C
H
D
GE
F
REF.
A
B
C
D
Millimeter
Min. Max.
1.24 1.65
3.99 4.60
2.40 2.90
1.90 2.44
REF.
E
F
G
H
Millimeter
Min. Max.
-
0.203
4.80 5.28
0.76 1.52
0.15 0.305
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating 25°C ambient temperature unless otherwise specified. Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameter
Symbol
SUF101A
Part Number
SUF102A SUF103A SUF104A
SUF105A
Unit
Maximum Repetitive Peak Reverse Voltage
VRRM
50
Maximum RMS Voltage
VRMS
35
Maximum DC Blocking Voltage
VDC
50
Maximum Average Forward Rectified
Current.375”(9.5mm) Lead Length at
IF
TA=55°C
Peak Forward Surge Current, 8.3ms single
half sine-wave superimposed on rated load
IFSM
Maximum Instantaneous Forward Voltage
@ 1.0A
VF
Maximum DC Reverse Current TA=25°C
at Rated DC Blocking Voltage TA=100°C
IR
Maximum Reverse Recovery Time 1
TRR
Typical Thermal Resistance3
RθJA
RθJL
Typical Junction Capacitance 2
CJ
Operating & Storage Temperature
TJ,TSTG
Notes:
1. Reverse Recovery Time test condition:IF=0.5A, IR=1A, IRR=0.25A
2. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
3. P.C.B Mounted on 0.2*0.2’’(5*5mm) Copper Pad Area.
100
200
400
70
140
280
100
200
400
1
30
0.95
1.3
5
100
35
85
35
10
-55~150
600
V
420
V
600
V
A
A
1.7
V
μA
nS
°C/W
pF
°C
http://www.SeCoSGmbH.com/
31-Jul-2013 Rev.D
Any changes of specification will not be informed individually.
Page 1 of 2