SMPD5100 Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – 100V, 5A Surface Mount Schottky Barrier Rectifiers
Elektronische Bauelemente
SMPD5100
100V, 5A
Surface Mount Schottky Barrier Rectifiers
RoHS Compliant Product
A suffix of “-C” specifies halogen & lead-free
FEATURES
Schottky Barrier Chip
High Thermal Reliability
Patented Super Barrier Rectifier Technology
High Forward Surge Capability
Ultra Low Power Loss and High Efficiency
Excellent High Temperature Stability
Plastic Material-UL Flammability 94V-0
TO-277D
PACKAGE INFORMATION
Package
MPQ
TO-277D
5K
Leader Size
13 inch
REF.
A
B
C
D
E
F
Millimeter
Min. Max.
1.65 1.95
5.3
5.5
1.7
1.9
3.8
4.2
0.45 0.65
0.8
1.0
REF.
G
H
I
J
K
L
Millimeter
Min. Max.
3.25 3.85
0.45 0.65
2.9
3.2
6.4
6.6
0.3 0.45
1.0
1.2
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(TA=25°C, unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, de-rate current by 20%.)
Parameter
Symbol
Rating
Unit
Maximum Peak Repetitive Reverse Voltage
VRRM
100
V
Maximum Working Peak Reverse Voltage
VRWM
100
V
Maximum DC Blocking Voltage
VDC
100
V
Maximum RMS Rectified Voltage
Maximum Average Rectified Output Current 1
VRMS
70
V
IO
5
A
Non-Repetitive Peak Forward Surge Current@ 8.3ms Single Half
Sine-Wave, Superimposed on Rated Load (JEDEC method) 2
IFSM
130
I2t Rating for Fusing@ t<8.3ms
I2t
70.135
Typical Thermal Resistance from Junction to Ambient
RθJA
80
Typical Thermal Resistance from Junction to Lead
RθJL
15
Operating Junction and Storage Temperature Range
TJ, TSTG
150, -55~150
Notes:
1. The data is tested on the condition that the ambient temperature is tested at a 9.5mm distance from the case.
2. FR-4 2oz 18.8mm × 14.4mm PCB with 5.6mm × 14.4mm copper pad.
A
A2S
°C / W
°C / W
°C
ELECTRICAL CHARACTERISTICS
Parameter
Forward Voltage Drop
Symbol
VFM
Peak Reverse Current at Rated DC Blocking Voltage
IR
Typ.
-
-
-
Max.
0.82
0.3
15
Unit
Test Condition
V IF=5A, TA=25°C
TA=25°C
mA
TA=100°C
http://www.SeCoSGmbH.com/
29-Nov-2016 Rev. A
Any changes of specification will not be informed individually.