English
Language : 

SM8150C_15 Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – 8.0 Amp Schottky Barrier Rectifiers
Elektronische Bauelemente
SM8150C
Voltage 150V
8.0 Amp Schottky Barrier Rectifiers
FEATURES
Low forward voltage drop
High current capability
High reliability
High surge current capability
Epitaxial construction
RoHS Compliant Product
A suffix of “-C” specifies halogen & lead-free
A
SMC
B
C
MECHANICAL DATA
Case: Molded plastic
Epoxy: UL94V-1 rate flame retardant
Lead: Lead solderable per MIL-STD-202
method 208 guaranteed
Polarity: As Marked
Mounting position: Any
Weight: 1.10 grams (Approximately)
PACKAGE INFORMATION
Package
MPQ
SMC
3K
Leader Size
13 inch
H
D
GE
F
REF.
A
B
C
D
Millimeter
Min. Max.
2.750 3.250
6.520 7.110
5.590 6.220
2.000 2.620
REF.
E
F
G
H
Millimeter
Min. Max.
-
0.203
7.750 8.130
0.760 1.520
0.150 0.305
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating 25°C ambient temperature unless otherwise s pecified. Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameter
Symbol
Rating
Unit
Maximum Recurrent Peak Reverse Voltage
Working Peak Reverse Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
See Fig. 1
Peak Forward Surge Current, 8.3 ms single half sine-wave
Superimposed on rated load (JEDEC method)
Maximum Instantaneous Forward
Voltage
TA=25°C
TA=125°C
Maximum DC Reverse Current at
Rated DC Blocking Voltage 4
Typical Junction Capacitance 1
TA=25°C
TA=125°C
Voltage Rate of Chance (Rated VR)
Typical Thermal Resistance 3
Typical Thermal Resistance 2
Operating & Storage Temperature
Note:
1. Measured at 1MHz and applied reverse voltage of 5.0 V D.C.
2. Thermal Resistance Junction to Lead.
3. Thermal Resistance Junction to Case.
4. Pulse test: 300µs pulse width, 1% duty cycle.
VRRM
VRWM
VR
IF(AV)
IFSM
VF
IR
CJ
dv/dt
RθJC
RθJL
TJ ,TSTG
150
150
150
8
150
0.87
0.73
0.1
8
200
10000
25
20
-50 ~ 150, -65 ~ 175
V
V
V
A
A
V
mA
pF
V / µS
°C / W
°C / W
°C
http://www.SeCoSGmbH.com/
23-Jan-2013 Rev.A
Any changes of specification will not be informed individually.
Page 1 of 2