SM5200B_15 Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – 5.0 Amp Schottky Barrier Rectifiers
Elektronische Bauelemente
SM5200B
Voltage 200V
5.0 Amp Schottky Barrier Rectifiers
RoHS Compliant Product
A suffix of “-C” specifies halogen & lead-free
FEATURES
 High Current Capability
 Extremely Low Thermal Resistance
 For Surface Mount Application
 Higher Temp Soldering : 250°C for 10 Seconds at Terminals
 Low Revise Current
MECHANICAL DATA
 Case: Molded Plastic
 Epoxy: UL 94V-0 Rate Flame Retardant
 Lead: Axial Leads, Solderable per MIL-STD-202
method 208 Guaranteed
 Polarity: Color Band Denotes Cathode End
 Mounting Position: Any
PACKAGE INFORMATION
Package
MPQ
SMB
3K
Leader Size
13’ inch
SMB
B
A
C
H
D
GE
F
REF.
A
B
C
D
Millimeter
Min. Max.
1.91 2.20
4.06 4.70
3.30 3.94
2.13 2.44
REF.
E
F
G
H
Millimeter
Min. Max.
-
0.203
5.08 5.59
0.76 1.52
0.15 0.305
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating 25°C ambient temperature unless otherwise specified. Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameter
Peak Repetitive Peak reverse voltage
Working Peak Reverse Voltage
Maximum DC Blocking Voltage
Average Forward Current @TJ=25°C
Peak Forward Current @ 8.3 ms Half Sine
Maximum Instantaneous
Forward Voltage
Maximum DC Reverse Current 4
Typical Junction Capacitance1
Typical Thermal Resistance 2
Typical Thermal Resistance 3
IFM = 5.0 A, TA = 25°C
IFM = 5.0 A, TA = 75°C
IFM = 5.0 A, TA = 125°C
TJ = 25°C
TJ = 100°C
Voltage Rate of Chance (Rated VR)
Operating Temperature Range
Storage temperature
Notes:
1. Measured at 1MHz and applied reverse voltage of 5.0 V D.C.
2. Thermal Resistance Junction to Ambient.
3. Thermal Resistance Junction to Case.
4. Pulse Test:Pulse Width = 300 μs, Duty Cycle ≦ 2.0%.
Symbol
VRRM
VRWM
VR
IF(AV)
IFSM
VF
IR
CJ
RJA
RJC
dv/dt
TJ
TSTG
Rating
200
200
200
5
150
0.88
0.78
0.72
40
700
250
65
20
10000
-50~150
-65~150
Unit
V
V
V
A
A
V
μA
pF
°C/W
°C/W
V / μs
°C
°C
http://www.SeCoSGmbH.com/
20-Dec-2013 Rev. B
Any changes of specification will not be informed individually.
Page 1 of 2