English
Language : 

SM320C_15 Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – 3.0 Amp Schottky Barrier Rectifiers
Elektronische Bauelemente
SM320C~SM3100C
Voltage 20V~ 100V
3.0 Amp Schottky Barrier Rectifiers
RoHS Compliant Product
A suffix of “-C” specifies halogen & lead-free
FEATURES
 RoHS Compliant Product
 Low forward voltage drop
 High current capability
 High reliability
 High surge current capability
 Epitaxial construction
MECHANICAL DATA
 Case:Molded Plastic
 Epoxy:UL 94V-0 Rate Flame Retardant
 Metallurgically bonded construction
 Polarity:Color Band Denotes Cathode End
 Mounting Position: Any
PACKAGE INFORMATION
Package
MPQ
SMC
3K
Leader Size
13 inch
SMC
B
A
C
H
D
GE
F
REF.
A
B
C
D
Millimeter
Min.
2.75
Max.
3.15
6.60 7.11
5.59 6.22
2.00 2.62
REF.
E
F
G
H
Millimeter
Min.
-
Max.
0.203
7.75 8.13
0.76 1.27
0.15 0.31
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating 25°C ambient temperature unless otherwise specified. Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameter
Symbol
SM320C
Part Number
SM340C SM360C
SM3100C
Unit
Peak Repetitive Peak reverse voltage
VRRM
Working Peak Reverse Voltage
VRSM
Maximum DC Blocking Voltage
VDC
Maximum Average Forward Current, See Fig. 1
IF
Peak Forward Surge Current @ 8.3 ms Half
Sine-Wave superimposed on rated load (JEDEC
IFSM
method)
Maximum Instantaneous Forward Voltage@ IF=3A
VF
Maximum DC Reverse Current
At Rated DC Blocking Voltage 3
TJ=25°C
TJ=100°C
IR
Typical Junction Capacitance 1
CJ
Voltage Rate of Chance (Rated VR)
dv/dt
Typical Thermal Resistance 2
Typical Thermal Resistance 4
RθJC
RθJL
Operating and Storage Temperature Range
TJ, TSTG
NOTES:
1. Measured at 1MHz and applied reverse voltage of 4.0 V D.C.
2. Thermal Resistance Junction to Case
3. Pulse Test:Pulse Width = 300 μs, Duty Cycle ≦ 2.0%.
4. Thermal Resistance Junction to Lead.
20
40
60
20
40
60
20
40
60
3
80
0.5
0.65
0.2
20
300
10000
25
20
-50 ~ 150
100
V
100
V
100
V
A
0.8
V
mA
pF
V / μS
°C / W
°C / W
°C
http://www.SeCoSGmbH.com/
16-Oct-2012 Rev.C
Any changes of specification will not be informed individually.