English
Language : 

SFG30U1200 Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – Voltage 1200V 30.0 Amp Low Loss Superfast Rectifier
Elektronische Bauelemente
SFG30U1200
Voltage 1200V
30.0 Amp Low Loss Superfast Rectifier
RoHS Compliant Product
A suffix of “-C” specifies and halogen free
FEATURES
Fast switching for high efficiency
Low noise
Low reverse leakage current
High voltage super FRD
PFC application
MECHANICAL DATA
Case:Molded plastic TO-220YA
Epoxy:UL 94V-0 rate flame retardant
Terminals:Solderable per MIL-STD-202
method 208
Mounting position:Any
Weight:2.07 grams
TO-220YA
REF.
Millimeter
Min. Max.
REF.
Millimeter
Min. Max.
A
-
10.5
I
12.90 13.35
B
1.58 1.82
J
4.44 4.70
C
1.33 1.45
K
1.14 1.40
D
15.3 16.2
L
5.84 6.86
E
3.50 3.91
M
2.25 2.60
1
2
F
2.90 3.25
N
0.35 0.64
G
1.22 1.43
P
-
1.7
H
0.68 0.94
Q
4.95 5.20
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameter
Symbol
Rating
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified
Current TC=80°C
Peak Forward Surge Current,8.3ms single Half sine-wave
superimposed on rated load (JEDEC method)
Instantaneous Forward Voltage
TJ=25°C
TJ=150°C
Maximum DC Reverse Current
At Rated DC Blocking Voltage
Maximum Reverse Recovery Time1
TJ=25°C
TJ=150°C
Maximum Reverse Recovery Time2
Typical Junction Capacitance3
Typical Thermal Resistance4
Operating Junction and Storage Temperature Range
Notes:
1. Reverse recovery test conditions IF= 0.5A, IR= 1.0A, IRR= 0.25A.
2. Reverse recovery test conditions IF= 15A, dIF / dt = 100A /us.
3. Junction Capacitance test conditions : VR = 10V,IF = 0.
4. Thermal Resistance junction to case.
VRRM
VRMS
VDC
IF(AV)
IFSM
VF
IR
TRR
TRR
CJ
RθJC
TJ, TSTG
1200
840
1200
30.0
250
3.2
2.8
250
1000
55
85
60
1.2
-65~175
Unit
V
V
V
A
A
V
µA
nS
pF
°C / W
°C
http://www.SeCoSGmbH.com/
14-Sep-2011 Rev. A
Any changes of specification will not be informed individually.