English
Language : 

SFG10ED200D Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – 10.0 Amp Super Fast Recovery Rectifier
Elektronische Bauelemente
SFG10ED200D~ SFG10ED600D
Voltage 200V ~ 600V
10.0 Amp Super Fast Recovery Rectifier
RoHS Compliant Product
A suffix of “-C” specifies and halogen free
FEATURES
Fast switching for high efficiency
Low forward voltage drop
High current capability
Low reverse leakage current
High surge current capability
MECHANICAL DATA
Case:Molded plastic TO-236
Epoxy:UL 94V-0 rate flame retardant
Terminals:Solderable per MIL-STD-202
method 208 guranteed
Mounting position:Any
Weight:1.70 grams
TO-263
REF.
A
b
L4
C
L3
L1
E
Millimeter
Min. Max.
4.00 4.85
0.68 1.00
0.00 0.30
0.36 0.53
1.50 REF
2.29 2.79
9.60 10.45
1
3
REF.
c2
b2
D
e
L
L2
Millimeter
Min. Max.
1.10 1.45
1.34 REF
8.0
9.15
2.54 REF
14.6 15.85
1.27 REF
2
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameters
Symbol
SFG10ED200D
Part Number
SFG10ED400D
SFG10ED600D
Unit
Maximum Recurrent Peak Reverse Voltage
VRRM
Maximum RMS Voltage
VRMS
Maximum DC Blocking Voltage
VDC
Maximum Average Forward Rectified
Current TL=100°C
Peak Forward Surge Current,8.3ms single Half
sine-wave superimposed on rated load (JEDEC
method)
IF(AV)
IFSM
Maximum Instantaneous Forward Voltage @ 5.0A
VF
Maximum DC Reverse Current
TJ=25°C
At Rated DC Blocking Voltage
TJ=125°C
IR
Maximum Reverse Recovery Time1
TRR
Typical Junction Capacitance2
CJ
Typical Thermal Resistance3
RθJC
Operating Junction and Storage Temperature Range TJ, TSTG
Notes:
1. Reverse recovery test conditions IF= 0.5A, IR= 1.0A, IRR= 0.25A.
2. Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts DC.
3. Thermal Resistance junction to lead.
200
140
200
0.95
400
280
400
10.0
100
1.25
10
250
25
65
2.2
-55~150
600
V
420
V
600
V
A
A
1.85
V
µA
nS
pF
°C W
°C
http://www.SeCoSGmbH.com/
14-Jun-2012 Rev. A
Any changes of specification will not be informed individually.
Page 1 of 2