English
Language : 

SFG08E200F Datasheet, PDF (1/4 Pages) SeCoS Halbleitertechnologie GmbH – Voltage 200V ~ 600V 8.0 Amp Super Fast Recovery Rectifier
Elektronische Bauelemente
SFG08E200F~SFG08E600F
Voltage 200V ~ 600V
8.0 Amp Super Fast Recovery Rectifier
RoHS Compliant Product
A suffix of “-C” specifies and halogen free
FEATURES
Fast switching for high efficiency
Low forward voltage drop
High current capability
Low reverse leakage current
High surge current capability
MECHANICAL DATA
Case:Molded plastic ITO-220A
Epoxy:UL 94V-0 rate flame retardant
Terminals:Solderable per MIL-STD-202
method 208
Polarity:Color band denotes cathode
Mounting position:Any
Weight:1.73 grams
1
ITO-220A
B
N
D
E
MA
132
H
JC
K
G
L
L
F
REF.
Millimeter
Min. Max.
REF.
Millimeter
Min. Max.
A
14.70 15.30
H
3.50 3.90
B
9.50 10.50
J
1.10 1.50
C
13.00
-
K
0.50 0.90
D
4.30 4.70
L
2.44 2.64
E
2.50 3.10
M
2.50 2.90
2
F
2.40 2.80
N
φ 3.1 φ 3.4
G
0.30 0.70
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameters
Symbol
SFG08E200F
Part Number
SFG08E400F
SFG08E600F
Maximum Recurrent Peak Reverse Voltage
VRRM
200
400
600
Maximum RMS Voltage
VRMS
140
280
420
Maximum DC Blocking Voltage
VDC
200
400
600
Maximum Average Forward Rectified
Current TC=100°C
IF(AV)
8.0
Peak Forward Surge Current,8.3ms single Half
sine-wave superimposed on rated load (JEDEC
IFSM
125
method)
Maximum Instantaneous Forward Voltage @ 8.0A
VF
0.95
1.25
2.4
Maximum DC Reverse Current At
Rated DC Blocking Voltage
TJ=25°C
TJ=125°C
IR
Maximum Reverse Recovery Time1
TRR
Typical Junction Capacitance2
CJ
Typical Thermal Resistance3
RθJC
Operating Junction and Storage Temperature Range TJ, TSTG
Notes:
1. Reverse recovery test conditions IF= 0.5A, IR= 1.0A, IRR= 0.25A.
2. Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts DC.
3. Thermal Resistance junction to case.
10
250
25
85
50
5.0
-55~150
Unit
V
V
V
A
A
V
µA
nS
pF
°C W
°C
http://www.SeCoSGmbH.com/
28-Jun-2011 Rev. A
Any changes of specification will not be informed individually.
Page 1 of 2