English
Language : 

SBR3045R Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – 30.0 Amp Schottky Barrier Rectifiers
Elektronische Bauelemente
SBR3045R
VOLTAGE 45 V
30.0 Amp Schottky Barrier Rectifiers
FEATURES
Low forward voltage drop
High current capability
High reliability
High surge current capability
Epitaxial construction
RoHS Compliant Product
A suffix of “-C” specifies halogen free
TO-220
B
N
D
E
MA
H
JC
MECHANICAL DATA
Case: Molded plastic
Epoxy: UL94V-0 rate flame retardant
Lead: Lead solderable per MIL-STD-202
method 208 guaranteed
Polarity: As Marked
Mounting position: Any
Weight: 1.93 grams (approximate)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25°C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.
K
G
L
L
F
REF.
A
B
C
D
E
F
G
Millimeter
Min. Max.
15.00 15.60
9.50 10.50
13.00 Min
4.30 4.70
2.50 3.10
2.40 2.80
0.30 0.70
REF.
H
J
K
L
M
N
Millimeter
Min. Max.
3.00 3.80
0.90 1.50
0.50 0.90
2.34 2.74
2.50 2.90
φ 3.1 φ 3.4
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Working Peak Reverse Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
Per Leg
Per Device
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Instantaneous
IF = 15 A, TA = 25°C, per leg
Forward Voltage
IF = 15 A, TA = 125°C, per leg
Maximum DC Reverse Current
TA = 25°C
at Rated DC Blocking Voltage(Note3)
TA = 100°C
Typical Junction Capacitance (Note 1)
Typical Thermal Resistance (Note 2)
Operating Temperature Range TJ
Storage Temperature Range TSTG
NOTES:
1. Measured at 1MHz and applied reverse voltage of 5.0V D.C.
2. Thermal Resistance Junction to Case.
3. Pulse Test: Pulse Width =300uS, Duty Cycle<=2%
SYMBOL
VRRM
VRSM
V DC
IF
IFSM
VF
IR
CJ
R θJC
dv / dt
TJ
TSTG
SBR3045R
45
45
45
15
30
180
0.57
0.52
0.5
12
2400
2.5
10000
-50 ~ +150
-65 ~ +175
UNITS
V
V
V
A
A
V
mA
pF
°C /W
V / µs
°C
°C
http://www.SeCoSGmbH.com/
07-Dec.-2010 Rev. A
Any changes of specification will not be informed individually.