English
Language : 

RS1505 Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – VOLTAGE 50V ~ 1000V 15.0 AMP Single Phase Bridge Rectifiers
RS1505 THRU RS1510
Elektronische Bauelemente
VOLTAGE 50V ~ 1000V
15.0 AMP Single Phase Bridge Rectifiers
RoHS Compliant Product
A suffix of “-C” specifies halogen-free.
ƔFEATURES
. Surge Overload rating – 220 ~ 400 amperes peak
. Ideal for printed circuit board
. Reliable low cost construction utilizing
Molded plastic technique
. Plastic material has underwrites laboratory
Flammability classification 94V-0
. Polarity: marked on body
. Mounting position: Any
. Weight: 12 grams
.935(23.7)
.895(22.7)
.15 X.23L
(3.8 X5.7L)
HOLE THRU
.700(17.8)
.660(16.8)
1.00
(25.4)
MIN.
.078
(2.0)
.780(19.8)
.740(18.8)
AC
+
.052(1.3)
.048(1.2)
DIA.
.220(5.6)
.180(4.6)
SPACING
.280(7.1)
.268(6.8)
Dimensions in inches and (millimeters)
ƔMAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 к ambient temperature unless otherwise specified.
Resistive or inductive load, 60Hz,
For capacitive load, derate current by 20%.
TYPE NUMBER
RS1505 RS151
Maximum Recurrent Peak Reverse Voltage
50
100
Maximum RMS Voltage
50
100
Maximum DC Blocking Voltage
50
100
Maximum Average Forward (with heatsink Note 2)
Rectified Output Current, at Ta=100к
(without heatsink)
Peak Forward Surge Current, 8.3 ms single
half Sine-wave superimposed
on rated load (JEDEC method)
Maximum Forward Voltage at 7.5A DC
Maximum DC Reverse Current Ta=25 к
at Rated DC Blocking Voltage Ta=100 к
I2t Rating for fusing (t<8.3ms)
Typical Junction Capacitance per element (Note 1)
Typical Thermal Resistance (Note 2)
Operating Temperature Range TJ
Storage Temperature Range TSTG
NOTES:
1. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
2. Device mounted on 300mm x 300mm x 1.6mm Cu Plate Heatsink.
RS152
200
200
200
RS154
400
400
400
15.0
3.2
RS156
600
600
600
240
1.05
10
500
240
60
0.8
-55 ~ +125
-55 ~ +150
RS158
800
800
800
RS1510
1000
1000
1000
UNITS
V
V
V
A
A
V
µA
A2S
pF
к/W
к
к
http://www.SeCoSGmbH.com/
01-Jun-2002 Rev. A
Any changing of specification will not be informed individual
Page 1 of 2