RGL34A Datasheet, PDF (1/2 Pages) Dc Components – TECHNICAL SPECIFICATIONS OF SURFACE MOUNT FAST RECOVERY RECTIFIER
RGL34A THRU RGL34M
Elektronische Bauelemente
VOLTAGE 50V ~ 1000V
0.5AMP Surface Mount Fast Recovery Rectifiers
RoHS Compliant Product
A suffix of "-C" specifies halogen-free
FEATURES
* Low forward voltage drop
* Low leakage current
* High reliability
MECHANICAL DATA
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
* Metallurgically bonded construction
* Polarity: Color band denotes cathode end
* Mounting position: Any
* Weight: 0.015 grams
DO-213AA/ SOD-80/ Mini Melf
.145(3.683) .022(.559)
.131(3.327) .016(.406)
SOLDERABLE
ENDS
.066(1.67)
.060(1.52)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Ta=55 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Instantaneous Forward Voltage at 0.5A
Maximum DC Reverse Current
Ta=25 C
at Rated DC Blocking Voltage
Ta=100 C
Maximum Reverse Recovery Time (Note 1)
Typical Junction Capacitance (Note 2)
Operating and Storage Temperature Range TJ, TSTG
RGL34A RGL34B RGL34D RGL34G RGL34J RGL34K RGL34M UNITS
50 100 200 400 600 800 1000 V
35
70 140 280 420 560 700 V
50 100 200 400 600 800 1000 V
0.5
A
30
A
1.3
V
5.0
µA
100
µA
150
250
500
nS
15
pF
-65 +175
C
NOTES:
1. Reverse Recovery Time test condition: IF=0.5A, IR=1.0A, IRR=0.25A
2. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
http://www.SeCoSGmbH.com
01-Jun-2002 Rev. A
Any changing of specification will not be informed individual