English
Language : 

QG5391A_15 Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – 1.5AMP Surface Mount Silicon Rectifiers
QG5391A THRU QG5399A
Elektronische Bauelemente
VOLTAGE 50V ~ 1000V
1.5AMP Surface Mount Silicon Rectifiers
RoHS Compliant Product
A suffix of "-C" specifies halogen & lead-free
SMA
FEATURES
* Ideal for surface mount applications
* Easy pick and place
* Built-in strain relief
* High surge current capability
MECHANICAL DATA
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
* Terminals: Solder plated, solderable per MIL-STD-202F,
method 208 guaranteed
* Polarity: Color band denotes cathode end
* Mounting position: Any
* Weight: 0.063 gram
A
B
D
G
F
Dimensions in Dimensions in
C
Millimeters
Inches
A 1.25 1.65 0.049 0.065
B 3.99 4.60 0.157 0.181
H
C 2.50 2.90 0.098 0.114
D 1.98 2.44 0.078 0.096
E 0.051 0.203 0.002 0.008
F 4.78 5.28 0.188 0.208
E
G 0.76 1.52 0.030 0.060
H 0.152 0.305 0.006 0.012
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Ta=75 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Instantaneous Forward Voltage at 1.5A
Maximum DC Reverse Current
Ta=25 C
at Rated DC Blocking Voltage
Ta=100 C
Typical Junction Capacitance (Note 1)
Typical Thermal Resistance RqJA (Note 2)
Operating and Storage Temperature Range TJ, TSTG
NOTES:
1. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
2. Thermal Resistance from Junction to Ambient.
QG5391A QG5392A QG5393A QG5395A QG5397A QG5398A QG5399A UNITS
50 100 200 400 600 800 1000 V
35
70 140 280 420 560 700 V
50 100 200 400 600 800 1000 V
1.5
A
50
A
1.15
V
10.0
µA
100
µA
30
pF
53
C/W
-65 +175
C
http://www.SeCoSGmbH.com
01-Jun-2006 Rev. B
Any changing of specification will not be informed individual
Page 1 of 2