QG301B_15 Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – 3.0Amp Surface Mount Silicon Rectifiers
QG301B THRU QG307B
Elektronische Bauelemente
VOLTAGE 50V ~ 1000V
3.0Amp Surface Mount Silicon Rectifiers
RoHS Compliant Product
A suffix of "-C" specifies halogen & lead-free
FEATURES
* Ideal for surface mount applications
* Easy pick and place
* Built-in strain relief
* High surge current capability
MECHANICAL DATA
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
* Terminals: Solder plated, solderable per MIL-STD-202F,
method 208 guaranteed
* Polarity: Color band denotes cathode end
* Mounting position: Any
* Weight: 0.102 gram
DO-214AA(SMB)
.083(2.11)
.075(1.91)
.096(2.44)
.083(2.13)
.050(1.27)
.030(0.76)
.185(4.70)
.160(4.06)
.155(3.94)
.130(3.30)
.012(0.31)
.006(0.15)
.008
MAX.
(.203)
.220(5.59)
.200(5.08)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Ta=75 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Instantaneous Forward Voltage at 3.0 A
Maximum DC Reverse Current
Ta=25 C
at Rated DC Blocking Voltage
Ta=100 C
Typical Junction Capacitance (Note 1)
Typical Thermal Resistance RJL (Note 2)
Operating and Storage Temperature Range TJ, TSTG
QG301B QG302B QG303B QG304B QG305B QG306B QG307B UNITS
50 100 200 400 600 800 1000 V
35
70 140 280 420 560 700 V
50 100 200 400 600 800 1000 V
3
A
80
A
1.20
V
5.0
µA
100
µA
40
pF
16
C/W
-65 +175
C
NOTES:
1. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
2. Thermal Resistance from Junction to Lead mounted on P.C.B. with 8.0 x 8.0mm copper pad areas.
http://www.SeCoSGmbH.com
01-Jun-2002 Rev. A
Any changing of specification will not be informed individual