GBU15005_11 Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – Voltage 50V ~ 1000V 15.0Amp Glass Passivited Bridge Rectifiers
Elektronische Bauelemente
GBU15005 ~ GBU1510
Voltage 50V ~ 1000V
15.0Amp Glass Passivited Bridge Rectifiers
RoHS Compliant Product
A suffix of “-C” specifies halogen & lead-free
FEATURES
Surge overload rating -240 amperes peak
Ideal for printed circuit board
Reliable low cost construction utilizing
molded plastic technique
Plastic material has Underwriters Laboratory
flammability classification 94V-0
Mounting position: Any
GBU
REF.
A
B
C
D
E
F
G
H
Millimeter
Min. Max.
21.80
18.30
3.37
22.20
19.10
3.53
17.27 18.29
3.2 x 45°
3.40 4.10
5.40 5.90
2.30 2.70
REF.
I
J
K
L
M
N
P
Q
Millimeter
Min. Max.
0.9
1.2
0.46 0.56
4.80 5.30
2.16 2.54
1.65 2.03
1.45 1.85
9.80 10.20
10.90 11.10
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating 25°C ambient temperature unless otherwise specified. Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameter
Symbol GBU
15005
GBU
1501
Part Number
GBU
1502
GBU
1504
GBU
1506
GBU
1508
Maximum Recurrent Peak Reverse Voltage
VRRM
50 100 200 400 600 800
Maximum RMS Bridge Input Voltage
VRMS
35
70 140 280 420 560
DC Blocking Voltage
VDC
50 100 200 400 600 800
Maximum Average Forward(with heat sink2)
15
Rectified Current @ TC=100°C(without heat
I(AV)
sink)
3.2
Peak Forward Surge Current 8.3 ms Single Half
Sine-Wave Super Imposed on Rated Load
IFSM
240
(JEDEC Method)
Maximum Forward Voltage @ 7.5A
VF
1.1
Maximum Reverse Current
TJ=25°C
10
at Rated DC Blocking Voltage TJ=125°C
IR
500
I2t Rating for Fusing (t<8.3ms)
I2t
200
Typical Junction Capacitance Per Element1
CJ
70
Typical Thermal Resistance
RθJC
2.2
Operating and Storage temperature range
TJ,TSTG
Notes:
1. Measured at 1.0MHz and applied reverse voltage of 4.0V DC.
2. Device mounted on 100mm*100mm*1.6mm Cu plate heat sink.