2SD1819A_11 Datasheet, PDF (1/2 Pages) SeCoS Halbleitertechnologie GmbH – NPN Plastic-Encapsulate Transistor
Elektronische Bauelemente
2SD1819A
0.1A , 60V
NPN Plastic-Encapsulate Transistor
24
RoHS Compliant Product
A suffix of “-C” specifies halogen & lead-free
FEATURES
High DC Current Gain.
Low collector to emitter saturation voltage VCE(sat).
Complementary to 2SB1218A
APPLICATION
General purpose amplification.
CLASSIFICATION OF hFE
Product-Rank 2SD1819A-Q 2SD1819A-R 2SD1819A-S
Range
160~260
210~340
290~460
Marking
ZQ
ZR
ZS
SOT-323
A
L
3
Top View
CB
1
1
2
K
E
D
F
G
H
3
2
J
REF.
A
B
C
D
E
F
Millimeter
Min. Max.
1.80 2.20
1.80 2.45
1.15 1.35
0.80 1.10
1.20 1.40
0.20 0.40
REF.
G
H
J
K
L
Millimeter
Min. Max.
0.100 REF.
0.525 REF.
0.08 0.25
-
-
0.650 TYP.
PACKAGE INFORMATION
Package
MPQ
SOT-323
3K
LeaderSize
7’ inch
ABSOLUTE MAXIMUM RATINGS (TA = 25°C unless otherwise specified)
Parameter
Symbol
Rating
Collector-Base Voltage
Collector-Emitter Voltage
Emitter-Base Voltage
Collector Current
Collector Power Dissipation
Thermal Resistance From Junction to Ambient
Junction & Storage temperature
VCBO
VCEO
VEBO
IC
PC
RθJA
TJ, TSTG
60
50
7
100
150
833
150, -55~150
Collector
3
1
Base
2
Emitter
Unit
V
V
V
mA
mW
°C / W
°C
ELECTRICAL CHARACTERISTICS (TA = 25°C unless otherwise specified)
Parameter
Symbol Min. Typ. Max. Unit
Collector-Base Breakdown Voltage V(BR)CBO
60
-
-
V
Collector-Emitter Breakdown Voltage V(BR)CEO
50
-
-
V
Emitter-Base Breakdown Voltage
V(BR)EBO
7
-
-
V
Collector Cut-Off Current
ICBO
-
-
0.1
µA
Base Cut-Off Current
ICEO
-
-
100
µA
Emitter Cut-off Current
IEBO
-
-
0.1
µA
DC Current Gain
hFE (1)
160
-
460
hFE (2)
90
-
-
Collector-Emitter Saturation Voltage VCE(sat)
-
-
0.3
V
Transition Frequency
fT
-
150
-
MHz
Collector Output Capacitance
Cob
-
3.5
-
pF
Test Conditions
IC=10µA, IE=0
IC=2mA, IB=0
IE=10µA, IC=0
VCB=20V, IE=0
VCE=10V, IB=0
VEB=7V, IC=0
VCE=10V, IC=2mA
VCE=2V, IC=100mA
IC=100mA, IB=10mA
VCE=10V, IC=2mA, f=200MHz
VCB=10V, IE=0, f=1MHz
http://www.SeCoSGmbH.com/
24-Feb-2011 Rev. B
Any changes of specification will not be informed individually.