English
Language : 

SS2413 Datasheet, PDF (5/9 Pages) SEC Electronics Inc. – Hall Latch - High Sensitivity
SS2413
Hall Latch - High Sensitivity
General Electrical Specifications
DC Operating Parameters TA = 25°C, VDD= 2.5V to 24V (unless otherwise specified)
Parameter
Symbol Test Conditions
Min Typ Max Units
Supply Voltage
Supply Current
Output Saturation Voltage
Output Leakage Current
VDD
IDD
VDSon
IOFF
Operating
B < BRP
IOUT = 20mA, B > BOP
B < BRP VOUT = 24V
2.5
3.5
120
1
24
V
5
mA
180 mV
10 µA
Output Rise Time
tr
RL = 1kΩ, CL = 20pF
0.15
µs
Output Fall Time
tf
RL = 1kΩ, CL = 20pF
0.15
µs
Maximum Switching Frequency
FSW
---
20
KHz
Package Thermal Resistance
RTH Single layer (1S) Jedec board
250
°C/W
Note: The output of SS2413 will be switched after the supply voltage is over 2.2V, but the magnetic characteristics won't be normal
until the supply is over 2.5V.
Magnetic Specifications
DC Operating Parameters VDD = 2.5 to 24V (unless otherwise specified)
Package Parameter
Symbol Test Conditions
Operating Point BOP
Ta=25°C
UA
Release Point
BRP
Vdd=5V DC
Hysteresis
BHYST
Operating Point BOP
Ta=25°C
SO
Release Point
BRP
Vdd=5V DC
Hysteresis
BHYST
Min Typ Max Units
5
30 55
G
-55 -30 -5
G
60
G
-55 -30 -10
G
5
30 55
G
60
G
Output Behavior versus Magnetic Pole
DC Operating Parameters TA = -40°C to 150°C, VDD = 2.5 to 24V (unless otherwise specified)
Test Conditions (UA) Test Conditions (SO) OUT
B < BRP
B > BRP
High
B > BOP
B < BOP
Low
The SOT-23 device is reversed from the UA package. The SOT-23 output transistor will be turned on(drops low) in the presence of a
sufficiently strong North pole magnetic field applied to the marked face and turned off(hoists high) in the presence of a sufficiently
strong South pole magnetic field.
5