English
Language : 

SS149 Datasheet, PDF (2/5 Pages) SEC Electronics Inc. – Unipolar Hall Switch-Low Sensitivity
SS149
Unipolar Hall Switch-Low Sensitivity
Glossary of Terms
MilliTesla (mT), Gauss
RoHS
Operating Point (BOP)
Release Point (BRP)
Units of magnetic flux density: 1mT = 10 Gauss
Restriction of Hazardous Substances
Magnetic flux density applied on the branded side of the package which turns the output
driver ON (VOUT = VDSon)
Magnetic flux density applied on the branded side of the package which turns the output
driver OFF (VOUT = high)
Pin Definitions and Descriptions
SOT Pin № SIP Pin № Name Type
1
1
VDD
Supply
2
3
OUT
Output
3
2
GND
Ground
Table 1: Pin definitions and descriptions
Function
Supply Voltage pin
Open Drain Output pin
Ground pin
Absolute Maximum Ratings
Parameter
Symbol
Supply Voltage
VDD
Supply Current
I DD
Output Voltage
V OUT
Output Current
I OUT
Storage Temperature Range TS
Table 2: Absolute maximum ratings
Value
28
50
28
50
-65 to 170
Units
V
mA
V
mA
°C
Operating Temperature Range
Temperature Suffix “E”
Temperature Suffix “K”
Temperature Suffix “L”
Symbol
TA
TA
TA
Value
-40 to 85
-40 to 125
-40 to 150
Units
°C
°C
°C
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-rated
conditions for extended periods may affect device reliability.
2