English
Language : 

6145 Datasheet, PDF (5/5 Pages) Schurter Inc. – IEC Appliance Inlet C14 with Circuit Breaker TA45
Power entry modules without line filter
www.schurter.com/pg05
6145
Technical data (continued)
Circuit breaker
Tripping characteristics
In < 3 A
[ min ] [ sec ]
10’000
60
30 2000
20 1000
10
500
5
200
100
1
50
Type
Rated current
Ambient temp.
TA45
In < 3 A
1-pole protected
2-pole protected
+23 °C
20
10
5
2
1
0,5
0,3
0,2
0,1
1,05 1,32
2
3
45
Multiple of rated current
[ x In ]
8 10
Tripping characteristics
In * 3…) 15 A
[ min ] [ sec ]
10’000
60
30 2’000
20 1’000
10
500
5
200
100
1
50
Type
Rated current
Ambient temp.
TA45
In ≥ 3... ≤ 15 A
1-pole protected
2-pole protected
+23 °C
20
10
5
2
1
0,5
0,3
0,2
0,1
1,05 1,32
2
3
45
Multiple of rated current
[ x In ]
8 10
Effect of ambient temperature 1)
The unit is calibrated for an ambient temperature of +23 °C. To
determine the rated current for a lower or higher ambient tempera-
ture, use a correction factor from the table below.
* Ambient temperature [°C] Correction factor
–10
0,89
–5
0,91
0
0,92
+23
1,00
+30
1,03
+40
1,08
+55
1,16
* Temperature must be measured at the rear of the breaker next to
the terminals after equipment operating temperature has been
reached.
1) Example
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at
+ 40 °C ambient temperature
6,0 A
+40 °C
1,08
6 A x 1,08 = 6,5 A
Order code (Order example)
Type
Order code TA 45
(2-pole rocker-switch without
accessories)
6145 . A B T W F 1 5 0 C 0 . 0 0 1
see table 1
Wiring
0 Without
1 With
2 Special (on request)
0 Without line filter
0 Without line filter
Please note that Schurter will establish an internal part number for logistical use in addition to the order code.
The format of this internal part number is, for example 6145.0031.001
The specifications, descriptions and illustrations indicated in this documCenot narneebcasteodrosn