English
Language : 

10700482 Datasheet, PDF (4/4 Pages) Schurter Inc. – TOUCHSCREEN
5.3 Exposure to constant temperature and humidity
Touch panel is put into a test machine at the condition of 60°C, 90%RH for 504 hours. Then it is left at the room
temperature for 24 hours or more. The measurement must satisfy the following:
- Circuit close resistance: as Sec. 3.3
- Circuit open resistance: as Sec. 3.4
- Contact bounce: as Sec. 3.5
- Linearity test: as Sec. 3.6
5.4 Thermal Shock
Touch panel is put into a test machine at the condition of –40°C for 30 minutes, and then 80°C for 30 minutes.
The process is repeated by 50 cycles. Then it is left at the room temperature for 24 hours or more. The measure-
ment must satisfy the following:
- Circuit close resistance: as Sec. 3.3
- Circuit open resistance: as Sec. 3.4
- Contact bounce: as Sec. 3.5
- Linearity test: as Sec. 3.6
6. Durability test:
6.1 Finger touches
Touch panel is hit 36 millions times with a silicone rubber of R8 finger, hitting rate is by 250g at 2 times per
second. The measurement must satisfy the following:
- Circuit close resistance: as Sec. 3.3
- Circuit open resistance: as Sec. 3.4
- Contact bounce: as Sec. 3.5
- Linearity test: as Sec. 3.6
7. Optical Performance:
7.1 Optical inspection method and optical defect standards refer to document. A001-2 Touch Screen Optical Quality
Standard.
7.2 Outside to Active Area : any optical defected in this area need to be ignored if no effected to touch screen func-
tion.
8. Others
8.1 Always store the touch screen in its original shipping container under normal conditions (20~25°C, 65% RH)
8.2 RoHS, this part is RoHS compliant
Zu Änd. Datum Name
Changes that contribute to technical improvement are subject to alternations
2007 Datum Name
Bearb.
Gepr.
Vert.
28.03.
28.03
Maurer
Maurer
TOUCHSCREEN
15,1", 5-Wire
AMT-02517-01
EDV-Datasheet
SPECIFICATIONS OF ANALOG RESISTIVE
PET-ON-GLASS TOUCH SCREEN
don’t change manually
Manufactured by Apex Material Technology Corp.
D 79346 Endingen
H 1070.0482
page 4 of 4 Index: -