English
Language : 

5707.0101.112 Datasheet, PDF (3/7 Pages) Schurter Inc. – Screw-on version from front or rear side, Screws with sealing are included
Power Entry Modules with Line Filter
www.schurter.com/PG06
Mounting standard version
A
3/4
2
1
B
31
2
C
41
2
5707
A) front view
B) detail front mounting type
C) detail rear mounting type
1) sealing of flange
2) sealing of fuseholder
3) sealing of screw hole (front mounting type: sealing ring on screw head)
4) sealing of screw hole (rear mounting type: sealing on screw thread)
Important:
- use supplied fuse caps (2) and mounting screws (3/4)
- optimal sealing requires even and solid panel opening
- recommended tightening torque for mounting screws (2/3/4): 0.5-0.8 Nm
- IP65 protection between the inlet and connector pins, but no IP rating between the connector pins and the plug of the power cord!
Technical Data of Filter-Components
Rated Current Filter-Type
[A]
1
Standard Version
2
Standard Version
4
Standard Version
6
Standard Version
8
Standard Version
1
Medical Version (M5)
2
Medical Version (M5)
4
Medical Version (M5)
6
Medical Version (M5)
8
Medical Version (M5)
2
Medical Version (M80)
Inductances Capacitance Capacitance
L [mH]
CX [nF]
CY [nF]
2 x 12
2 x 5.2
2x2
2 x 0.8
2 x 0.4
2 x 12
2 x 5.2
2x2
2 x 0.8
2 x 0.4
2 x 5.2
100
2.2
100
2.2
100
2.2
100
2.2
100
2.2
100
-
100
-
100
-
100
-
100
-
100
0.47
R [MΩ]
1
1
1
1
1
1
1
1
1
1
1
Diagrams
Standard version
Medical version M5
L
1) PE
N
1) Line
2) Load
F1
L1
R
Cx
F2
L2
L'
L
Cy PE' 2) 1) PE
Cy N'
N
1) Line
2) Load
F1
L1
R
Cx
F2
L2
L'
PE' 2)
N'
EMC Products
3