English
Language : 

GRF4 Datasheet, PDF (2/4 Pages) Schurter Inc. – IEC Appliance Inlet C14 with Filter, "Lock and Shield" Mounting
GRF4
www.schurter.com/pg06
Technical Data of Filter-Components
Rated Current Filter-Type
[A]
0.5
Standard Version
1
Standard Version
3
Standard Version
6
Standard Version
10
Standard Version
15
Standard Version
0.5
Medical Version (M5)
1
Medical Version (M5)
3
Medical Version (M5)
6
Medical Version (M5)
10
Medical Version (M5)
15
Medical Version (M5)
Inductances Capacitance Capacitance
L [mH]
CX [nF]
CY [nF]
2 x 24
100
2.2
2 x 12
100
2.2
2 x 2.5
100
2.2
2 x 0.78
100
2.2
2 x 0.225
100
2.2
2 x 0.075
100
2.2
2 x 24
100
-
2 x 12
100
-
2 x 2.5
100
-
2 x 0.78
100
-
2 x 0.225
100
-
2 x 0.075
100
-
Dimensions
Step 1
Step 2
Step 3
Power Entry Modules with Line Filter
R [MΩ]
-
-
-
-
-
-
1
1
1
1
1
1
Place the socket in top edge of the panel
cut-out.
Step 4
Push the socket upwards.
Push the socket forward into the panel
cut-out.
Release the socket. The component is
self adjusting.
Diagrams
Standard version
Medical version
1) Line
2) Load
1) Line
2) Load