English
Language : 

609861 Datasheet, PDF (2/2 Pages) Schurter Inc. – Breaking capacity
ASO 10.3x38
www.schurter.com/pg01_2
Variants
Rated Cur-
rent [A]
Rated Vol- Breaking
tage [VDC] Capacity
Power Dissi- Melting I²t 20
pation 1.0 In kA typ. [A²s]
typ. [mW]
1
1000 1)
2
1000 1)
3
1000 1)
4
1000 1)
5
1000 1)
6
1000 1)
8
1000 1)
10
1000 1)
12
1000 1)
15
1000 1)
20
1000 1)
25
1000 1)
30
1000 1)
1) 20 kA @ 1000 VDC, L/R < 2ms
778
0.325 l l
1905
1.012 l l
2000
10.15 l l
2200
9.46 l l
1858
25.2 l l
1952
46.3 l l
1790
130 l l
2580
252 l l
2896
360 l l
1914
505 l l
2516
1313 l l
2981
2371 l l
3923
2679 l l
Packaging Unit
Bulk (10 pcs.)
Order Number
0090.0001
0090.0002
0090.0003
0090.0004
0090.0005
0090.0006
0090.0008
0090.0010
0090.0012
0090.0015
0090.0020
0090.0025
0090.0030
Time-Current-Curves
10000
1000
100
10
1
0.1
0.01
0.001
0.0001
1
10
Current in Amperes
0090.0001
0090.0002
0090.0003
0090.0004
0090.0005
0090.0006
0090.0008
0090.0010
0090.0012
0090.0015
0090.0020
0090.0025
0090.0030
100
1000
Non resettable fuses
TFheusspeescifications, descriptions and illustrations indicated in this document are based on

current information. All content is subject to modifications and amendments.