English
Language : 

TA45-2R Datasheet, PDF (1/8 Pages) Schurter Inc. – Circuit Breaker for Equipment thermal, 2 pole, Rocker actuation
Thermal (T- and TA-Line)
www.schurter.com /PG17_20
Circuit Breaker for Equipment thermal, 2 pole, Rocker actuation
TA45-2R
Description
- Thermal circuit breaker
- 1 or 2 pole thermal overload protection
- Positively trip-free release
- High configurability
- Rocker non-illuminated or illuminated
- Snap-in version
- Quick connect terminal 6.3 x 0.8 mm or screw clamp terminal M3.5 x
6 mm (lineside P1, P2)
Approvals
- Approval Reference Type: TA45
- IEC Standard: IEC 60934
- UL Standard: UL 1077
- CSA Standard: CSA C22.2 No. 235
- GB Standard: GB 17701
Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current range AC
Conditional short circuit ca-
pacity
Degree of Protection
Dielectric Strength
Insulation resistance
Endurance typical
␣
␣
240 V
60 V
0.05 - 20 A
IEC: Inc, PC1, AC 240 V: 1 kA
from front side IP 40 acc. to IEC 60529
4 kVAC
500 VDC > 100 MΩ
mechanical: 50'000 switching cycles
AC: 1 x Ir:
50'000 switching cycles
DC: 1 x Ir:
50'000 switching cycles
Applications
- Power tools
- Industrial appliances
- Power supplies
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Distributor-
Stock-Check, Detailed request for product, Product News
Overload
␣
Ambient temperature
Vibration Resistance
Shock Resistance
Tripping Type
Actuation type
Weight
AC: min. 40 trips
@ 6 x Ir
DC: min. 40 trips
@ 4 x Ir
-10 °C to 55 °C
± 0.75 mm @ 5 - 60 Hz
acc. to IEC 60068-2-6, test Fc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc
30 G / 18 ms
acc. to IEC 60068-2-27, test Ea
Thermal
Rocker
30 - 35 g
Dimension
Quick connect terminal
Screw clamp terminal
25
48
16
23.7
44.1
P1 a
3
5
5.3
26.7
8.4
A)
10.8
21.5
A) Quick connect terminal, IEC 61210, A6.3-0.8 mm
P1 a
3
5
B)
10.8
10.8
B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm