English
Language : 

OMF250_16 Datasheet, PDF (1/3 Pages) Schurter Inc. – Surface Mount Fuse, 11 x 4.6 mm, Quick-Acting F, 250 VAC, 250 DC
Non resettable fuses
www.schurter.com /PG01_2
Surface Mount Fuse, 11 x 4.6 mm, Quick-Acting F, 250 VAC, 250 DC
OMF 250
Exemplary part photo depending on
part no.
IEC 60127-4 · 250 VAC · 250 VDC · Quick-Acting F
Description
- Directly solderable on printed circuit boards
Standards
- IEC 60127-4/2
- UL 248-14
- CSA C22.2 no. 248.14
- Telcordia GR-1089
- UL 60950 / IEC 60950
- ITU-T K.20 and K.21
- TIA-968-A
Approvals
- VDE Certificate Number: 106328
- UL File Number: E41599
Technical Data
Rated Voltage
Rated current
Breaking Capacity
Characteristic
Mounting
Admissible Ambient Air Temp.
Climatic Category
Material: Housing
Material: Terminals
Unit Weight
Storage Conditions
Product Marking
250 VAC, 250 VDC
0.25 - 4 A
100 A
Quick-Acting F
PCB,SMT
-55 °C to 125 °C
55/125/21 acc. to IEC 60068-1
Thermoplastic, UL 94V-0
Tin-Plated Copper Alloy
0.36 g
0 °C to 60 °C, max. 70% r.h.
, Type, Rated current, Characteristic,
Breaking Capacity, Approvals
Applications
- Primary protection on SMD PCBs
References
Packaging Details
Fuse Kit  Fuse Kit OMF
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Packaging
details, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS,
REACH, Distributor-Stock-Check, Detailed request for product
Soldering Methods
Solderability
Resistance to Soldering Heat
Load Humidity Test
Moisture Resistance Test
Terminal Strength
Thermal Shock
Case Resistance
Mechanical Shock
Vibration, High Frequency
Resistance to Solvents
Flammability
Reflow, Wave
Soldering Profile
245 °C / 3 sec acc. to IEC 60068-2-58,
Test Td
260 °C / 10 sec acc. to IEC 60068-2-58,
Test Td
MIL-STD-202, Method 103B
0.1 x In @ 0.85 r.H. @ 85°C
MIL-STD-202, Method 106E
(50 cycles in a temp./mister chamber)
MIL-STD-202, Method 211A
(Deflection of board 1 mm for 1 minute)
MIL-STD-202, Method 107D
(200 air-to-air cycles from -55 to
+125°C)
acc. to EIA/IS-722, Test 4.7
>100 MΩ (between leeds and body)
MIL-STD-202, Method 213B
(Shock 50g, half sine wave, 11 ms)
MIL-STD-202, Method 204D
Shock 20 gn, 20 min, 10-2 kHz, 12 cyc.
MIL-STD-202, Method 215A
min. UL 94V-1
(acc. to EIA/IS-722, Test 4.12)
Fuses