MSF Datasheet, PDF (1/3 Pages) Schurter Inc. – Subminiature Fuse, 6.4 mm, Quick-Acting F, 125 VAC, 125 VDC | |||
|
Non resettable fuses
Subminiature Fuse, 6.4 mm, Quick-Acting F, 125 VAC, 125 VDC
MSF 125
www.schurter.com/pg01_2
UL 248-14 · 125âVAC · 125âVDC · Quick-Acting F
Description
- Directly solderable on printed circuit boards
Standards
- UL 248-14
- CSA C22.2 no. 248.14
Approvals
- UL File Number: E41599
Technical Data
Rated Voltage
Rated Current
Breaking Capacity
Characteristic
Mounting
Admissible Ambient Air Temp.
Climatic Category
Material: Housing
Material: Terminals
Unit Weight
Storage Conditions
Product Marking
125âVAC, 125âVDC
0.1 - 5âA
100âA
Quick-Acting F
PCB,THT
-55â°C to 125â°C
55/125/21 acc. to IEC 60068-1
Thermoplastic, UL 94V-0
Tin-Plated Copper
0.34 g
0â°C to 60â°C, max. 70% r.h.
, Type, Current, Voltage, Characteri-
stic, Approvals
Dimensions
6.4 mm
References
General Product Information
Packaging Details
Corresponding Fuseholder   FME;  FMR;  FMS (125V)
Weblinks
Approvals, RoHS, CHINA-RoHS, e-Store, Distributor-Stock-Check,
Accessories, Product Change Notification (PCN)
Soldering Methods
Solderability
Resistance to Soldering Heat
Life Test
Terminal Strength
Case Resistance
Mechanical Shock
Vibration, High Frequency
Resistance to Solvents
Flammability
Wave, Iron
235â°C / 2âsec acc. to IEC 60068-2-20,
Test Ta, method 1
260â°C / 5âsec acc. to IEC 60068-2-20,
Test Tb, method 1A
MIL-STD-202, Method 108A
(1000h @ 0.42*In @ 70°C)
MIL-STD-202, Method 211A
(Deflection of board 1 mm for 1 minute)
acc. to EIA/IS-722, Test 4.7
>100 MΩ (between leeds and body)
MIL-STD-202, Method 213B
(Shock 50gn, half sine wave, 11 ms)
MIL-STD-202, Method 204D
(Shock 20 gn, 20 min, 10-2 kHz, 12
cyc.)
MIL-STD-202, Method 215A
min. UL 94V-1
(acc. to EIA/IS-722, Test 4.12)
ø 6.4
ø 6.4
ø 0.62
1.8
2.54
ø 0.62
1.8
2.54
Drilling diagram
+0.1
10
2.54
Pre-Arcing Time
Rated Current In 1.5 x In  max. 2.0 x In  max.
0.1 A - 5 A
10 min
5s
2.75 x In  4.0 x In  max.
max.
300 ms
30 ms
10.0 x In Â
max.
4 ms
Fuses
|
▷ |