English
Language : 

KM00120511 Datasheet, PDF (1/4 Pages) Schurter Inc. – IEC Appliance Inlet C14 with Fuseholder 2-pole, Line Switch 1- or 2-pole
Power entry modules without line filter
IEC Appliance Inlet C14 with Fuseholder 2-pole, Line Switch 1- or 2-pole
www.schurter.com/pg05
KM
Plug removal necessary for fuse
replacement
KM with shield
C14
70° C
Description
- Panel Mount:
Snap-in version from front side
- 3 Functions:
Appliance Inlet Protection class I, Line Switch 2-pole, Fuseholder for
fuse-links 5 x 20 mm 1‑ or 2‑pole
- Quick connect terminals 4.8 x 0.8 mm
- Alternative: version with line filter  KMF 
- Alternative: version for screw mounting  DD11 
- With cover on rear-side
Approvals
- VDE License Number: 40021981
- UL License Number: E93617
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
10 A / 250 VAC; 50 Hz
10 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 4.8 x 0.8 mm
, tin-plated
Snap-in: 1/1.5/2/2.5 mm
(all steps with one variant)
Thermoplastic, black, UL 94V-0
Characteristics
- Ultra-compact design. Small dimensions in front of and behind the pa-
nel
- All single elements are already wired
- For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuse drawer can only be opened with the aid of a tool
The fuseholder is accessible from the equipment front
- Ideal for application with high transient loads
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
- Fuse drawer 1-pole, plus spare fuse case
- Fuse drawer 2-pole, with shorting bar
- Line switch 1-pole
- Other rocker marking
- Protection class II, 70°C
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Appliance Inlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.4 W (2-pole) per
pole
Choose fuse-links for 2-pole version
in such a way that the typical power
acceptance is less than 1.4 W for each
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
Connectors