KFX Datasheet, PDF (1/3 Pages) Schurter Inc. – IEC Appliance Inlet C14 with Filter, Increased Dielectric Strength | |||
|
Power Entry Modules with Line Filter
IEC Appliance Inlet C14 with Filter, Increased Dielectric Strength
www.schurter.com/pg06
KFX
C14
70° C
Description
- Panel Mount:
Screw-on mounting from front side
- 2 Functions:
Appliance Inlet Protection class I, Line-filter in standard version
- Quick connect terminals 6.3 x 0.8 mm
Approvals
- VDE License Number: 40004665
- UL License Number: E72928
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Impulse Withstand Voltage
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
1 - 10âA @ Ta 40 °C / 250âVAC; 50âHz
1 - 10âA @ Ta 40 °C / 125âVAC; 60âHz
standard < 0.5âmA (250âV / 60âHz)
> 1.7âkVDC between L-N
> 2.7âkVDC between L/N-PE
Test voltage (2âsec)
> 4âkV between L-N (CX1)
> 5âkV between L/N-PE
-25â°C to 85â°C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8âmm
Mounting screw torque max 0.5âNm
Thermoplastic, black, UL 94V-0
Characteristics
- Compact design with optimal shielding
- All single elements are already wired
- Universal line filter for standard applications
With enhanced surge withstand voltage
- Qualified for use in equipment according IEC/EN 60950
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Appliance-Inlet/-Outlet
Line Filter
MTBF
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10âA,
Protection Class 1
Standard Version, IEC 60939, IEC
60601â1, UL 1283, UL 544, EN 133
200, CSA C22.2 no. 8
Technical details
> 3'100'000âh acc. to MIL-HB-217 F
Dimensions
R 6.6
R 3.5
KFX
R3
19.7
23.3±0.3
54
3.5
61.5
(5.5)
67
M3
21.5+00..50
EMC Products
|
▷ |