KEA Datasheet, PDF (1/4 Pages) Schurter Inc. – IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole | |||
|
Power entry modules without line filter
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole
www.schurter.com/pg05
KEA
Plug removal necessary for fuse
replacement
KEA
KEA
C14
70° C
Description
- Panel Mount:
Screw-on version from front or rear side, snap-in version from front
side
- 3 Functions:
Appliance Inlet Protection class I, Fuseholder for fuse-links 5 x 20 mm
1â or 2âpole, with or without voltage selector (step switch)
- Quick connect terminals 4.8 x 0.8 mm
- Alternative: version with line filter  KFA
Approvals
- VDE License Number: 40012272
- UL License Number: E93617
- CSA License Number: 38456
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
10âA / 250âVAC; 50âHz
10âA / 250âVAC; 60âHz
> 3âkVAC between L-N
> 4âkVAC between L/N-PE
(1âmin/50âHz)
-25â°C to 70â°C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 4.8 x 0.8 mm
Screw: max 8âmm
Mounting screw torque max 0.5âNm
Snap-in: 1.5/2/2.5 mm
Thermoplastic, black, UL 94V-0
Characteristics
- Available with or without internal connections
- Plug removal necessary for fuse-link replacement
The fuse drawer "Fingergrip" can be removed by hand
For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
- With solder terminals
- Fuse drawer with other voltage values
- For protection class II
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Appliance Inlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Voltage Selectors
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10âA,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20âmm
5 x 20: 2âW (1 pole)/ 1.6âW (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
optional, step, 2-4 digits
Connectors
|
▷ |