English
Language : 

GRM4 Datasheet, PDF (1/4 Pages) Schurter Inc. – mounting, line switch, fuseh. 5x20 mm with/without voltage sel
Power entry modules with line filter
www.schurter.com/pg06
GRM4
"Lock and shield" mounting, line switch, fuseh. 5x20 mm with/without voltage sel. (series-parallel)
Standard- or Medical-Filter
Snap-In Version
GRM4: with shield and line filter
C14
70° C
Description
- Panel Mount:
Snap-In Version from rear-side
- 5 Functions:
Inlet Protection class I, Line switch 2-pole, with or without Fuseholder
for fuse-links 5 x 20 mm, with or without voltage selector, Line filter in
standard and medical version
- On phase-out, not recommended for new design
Approvals
- VDE License Number: 118913
- UL License Number: E72928
- CSA License Number: 701867
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
0.5 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
0.5 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 4.8 x 0.8 mm
Solder terminal on request
Solder terminals for voltage selector
Snap-in: 1.5 mm
(other on request)
Thermoplastic, black, UL 94V-0
Characteristics
- Ultra-compact design
Time saving "Lock and Shield" snap-in design for rear-panel mounting
- All single elements are already wired
- Fuseholder on the inside of the equipment prevents accidental use of
incorrect fuse-links by the user
- Voltage selector for two voltage ranges
Innovative EMC-shielding with flexible steel segments for an excellent
contact to the panel
- Insulation cover on the rear-side
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
- Panel thickness 1.0 / 2 / 2.5 mm (max.)
- Fuseholder 1‑pole
- Line switch 1-pole
- Voltage selector with other marking
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check,
Distributor-Stock-Check
Appliance-Inlet /-Outlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Voltage selector
Line Filter
MTBF
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
condition) pin-temperature 70 °C, 10 A,
Protection class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
optional, jumper, 2 digits
Standard and Medical Version, IEC
60939, IEC 60601‑1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 1'400'000 h acc. to MIL-HB-217 F
EMC products