FPG6 Datasheet, PDF (1/2 Pages) Schurter Inc. – Shock-Safe Fuseholder, 5 x 20 mm, Slot, Press, IEC 60335-1 | |||
|
Fuseholders
Shock-Safe Fuseholder, 5 x 20 mm, Slot, Press, IEC 60335-1
www.schurter.com/pg02
FPG6
250 VAC · 2.5âWâ/â10âA (VDE)16âA (UL/CSA)
Description
- Meets the new requirements of IEC 60335-1 Ed. 4.0 for appliances in
unattended use (clause 30.2.3). This includes the enhanced require-
ments of glow wire tests acc. to IEC 60695-2-11 to -13. Order numb-
ers: xxxx.xxxx.15
- Press-fit mount, secured with potting compound on the rear side
Standards
- IEC 60127-6
- UL 4248-1 / UL 512
- CSA C22.2 no. 39
Approvals
- VDE License Number: 127216
- UL File Number: E39328
Technical Data
Shocksafe Category
Fuse-Link
Mounting
Mounting
Terminal
Rated Voltage
Rated Current
Rated Power Acceptance IEC
Degree of Protection
Protection Class
Admissible Ambient Air Temp.
Climatic Category
Material: Socket
Material: Terminals
Unit Weight (Socket/Cap)
Storage Conditions
Product Marking
PC2
5 x 20âmm
Panel Mount, Front-Side
Press-Fit
Solder or Quick-Connect 4.8 x 0.5 mm
250âVAC
10âA (VDE), 16âA (UL/CSA)
2.5âW / 10âA @ Ta 23â°C
Admissible power acceptance at hig-
her ambient temperature see derating
curves
IP 40
Suitable for appliances with protection
class 1 or 2 acc. to IEC 61140
-40â°C to 85â°C
40/085/21 acc. to IEC 60068-1
Thermoplastic, black, UL 94V-0
Tin-Plated Copper Alloy
5.3 g
0â°C to 60â°C, max. 70% r.h.
, Type, Voltage, Power Acc./Current
Rating, Approvals
Applications
- Industrial electronic
- Household appliances
- Medical equipments
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, e-Store, Distributor-Stock-Check,
Accessories, Product Change Notification (PCN)
Soldering Methods
Solderability
Resistance to Soldering Heat
Contact Resistance
Dielectric Strength
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category
Pollution Degree
Resistance to Vibration
Panel Thickness s
Iron
350â°C / 2âsec acc. to IEC 60068-2-20,
Test Ta, method 2
350â°C / 10âsec acc. to IEC 60068-2-20,
Test Tb, method 2
< 5âmΩ at 20 mV
> 3âkV between L-N
> 4âkV between L/N-PE
(50âHz; 1 min)
> 2.5âkV between L-N
> 6âkV between L/N-PE
> 10âMΩ between L-N
> 100âMΩ between L/N-PE
(500âVDC; 1 min)
I - II acc. to IEC 60664-1
1 - 3 acc. to IEC 60664-1
acc. to IEC 60068-2-6, test Fc
max 2.5âmm
Fuses
|
▷ |