English
Language : 

FAS Datasheet, PDF (1/2 Pages) Schurter Inc. – Shock-Safe Fuseholder, 5 x 20 mm, Fingergrip, horizontal, PC1
Fuseholders
Shock-Safe Fuseholder, 5 x 20 mm, Fingergrip, horizontal, PC1
www.schurter.com/pg02
FAS
Fingergrip
250 VAC · 1.6 W / 6.3 A
Description
- Shocksafe Category PC1
Standards
- IEC 60127-6
Technical Data
Shocksafe Category
Fuse-Link
Mounting
Terminal
Rated Voltage
Rated Current
Rated Power Acceptance IEC
Degree of Protection
Protection Class
Admissible Ambient Air Temp.
Climatic Category
Material: Socket
Material: Cap
Material: Terminals
Unit Weight (Socket/Cap)
Storage Conditions
Product Marking
PC1
5 x 20 mm
PCB
Solder THT
250 VAC
6.3 A
1.6 W / 6.3 A @ Ta 23 °C
Admissible power acceptance at hig-
her ambient temperature see derating
curves
IP 40
Suitable for appliances with protection
class 1 or 2 acc. to IEC 61140
-40 °C to 85 °C
40/085/21 acc. to IEC 60068-1
Thermoplastic, UL 94V-0
Thermoset, UL 94V-0
Tin-Plated Copper Alloy
4.7 g
0 °C to 60 °C, max. 70% r.h.
, Voltage, Current, Approvals
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, e-Store, Distributor-Stock-Check,
Accessories, Product Change Notification (PCN)
Soldering Methods
Solderability
Resistance to Soldering Heat
Contact Resistance
Dielectric Strength
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category
Pollution Degree
Wave
235 °C / 2 sec acc. to IEC 60068-2-20,
Test Ta, method 1
260 °C / 10 sec acc. to IEC 60068-2-20,
Test Tb, method 1A
< 5 mΩ at 20 mV
> 3 kV between L-N
(50 Hz; 1 min)
> 4 kV between L-N
> 10 MΩ between L-N
(500 VDC; 1 min)
I - III acc. to IEC 60664-1
1 - 3 acc. to IEC 60664-1
Abmessungen
31 mm
31
84
5.2
12.5
+0.2
0
12±0.2
6
Drilling diagram
+0.1
1.3 0
12.5 ±0.1
Fuses