English
Language : 

DKLL-1 Datasheet, PDF (1/2 Pages) Schurter Inc. – Compensated High Inductance Choke, 1-phase
Suppression Chokes
Compensated High Inductance Choke, 1-phase
DKLL-1
www.schurter.com/pg81_82
Description
- Current compensated choke
- 1‑phase choke
- THT-terminals
- Flange for mounting onto printed circuit board
- Fully potted resign
Standards
- EN 60938
- IEC 60950
- EN 55011/55014
- VDE 0871/0875
Technical Data
Rated voltage
Rated voltage
Rated Current
Rated inductance
Power Operating Frequency
Terminal technic
Weight
Material: Housing
Sealing Compound
up to 540 VAC
up to 760 VDC
4 - 7 A @ Ta 40 °C
14 - 60 mH, Tol. -30% +50%
50 - 400 Hz
THT
145 - 505 g
UL 94V-0
UL 94V-0
Dimensions
Case 31-2P
80
12
65
4
50.8
6.8
Applications
- Placed in front of frequency converter
- Stepper motor drives
- UPS-systems
- Inverter
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, e-Store, Distributor-Stock-Check
Test Voltage
Isolation Voltage
Climatic Category
Allowable Operation Temp.
2.5 kV, 50 Hz, 2 sec, winding to winding
2.5 kV eff., 50 Hz, 2 sec, winding to
ambient
25/100/21 acc. to IEC 60068-1
-25 °C to 100 °C
Case 46-2P
50
3.1
40
2.5
30.8
5.8
55 1)
1) Spacing given at pin base
(0.8)
10
35 1)
(0.8)
10