Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current range AC
Conditional short circuit ca-
pacity
Degree of Protection
Dielectric Strength
Insulation resistance
Endurance typical
␣
␣
240 V; 50/60 Hz
32 V
0.05 - 20 A
0.05...20 A: 2 kA, SC (C1) @ 240 VAC
from front side IP 40 acc. to IEC 60529
50 Hz: > 2.5 kV
Impulse 1.2/50 μs: > 4 kV
500 VDC > 100 MΩ
mechanical: 50'000 switching cycles
AC: 1 x Ir, cos φ 0.6:
30'000 switching cycles
DC: 1 x Ir, L/R = 2 - 3 ms:
50'000 switching cycles
Applications
- Power tools
- Industrial appliances
- Equipment for construction
- Cleaning equipment
- Commercial and household kitchen appliances
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Distributor-
Stock-Check, Detailed request for product, Product News
Overload
␣
Ambient temperature
Vibration Resistance
Shock Resistance
Tripping Type
Actuation type
Weight
IEC: min. 40 trips
@ 6 x Ir, cos φ 0.6
UL / CSA: min. 50 trips
@ 1.5 x Ir, cos φ 0.75
-30 °C to 60 °C
± 0.75 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Tc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Tc
30 G / 18 ms
acc. to IEC 60068-2-27, test Ea
Thermal
Rocker
16.5 - 18.5 g
Dimension
36
17.5
34
9.9
14.5
+0.2
0
L
5
2.8 x 0.4 mm
21.3
33.8
2.3
12.5
14.5
6.3 x 0.8 mm
+0.3
Panel 1.0 − 4.0 mm
Circuit Breakers