English
Language : 

43013211 Datasheet, PDF (1/4 Pages) Schurter Inc. – IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole for PCB
Power entry modules without line filter
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole for PCB
KEA-Print
www.schurter.com/pg05
Plug removal necessary for fuse
replacement
KEA-Print
C14
KEA-Print
70° C
Description
- Panel Mount:
Screw-on version from front or rear side, snap-in version from front
side
- 2 Functions:
Appliance Inlet Protection class I, Fuseholder for fuse-links 5 x 20 mm
1‑ or 2‑pole
- For PCB mounting
Approvals
- VDE License Number: 40012272
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
10 A / 250 VAC; 50 Hz
10 A / 250 VAC; 60 Hz
> 3 kVAC between L-N
> 4 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
For PCB 1,6 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1.5/2/2.5 mm
Thermoplastic, black, UL 94V-0
Characteristics
- All single elements are already wired
- Plug removal necessary for fuse-link replacement
The fuse drawer "Fingergrip" can be removed by hand
For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
- With solder terminals
- Fuse drawer with other voltage values
- For protection class II
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Appliance Inlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Connectors