1092 Datasheet, PDF (1/7 Pages) Schurter Inc. – IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole | |||
|
Power entry modules without line filter
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole
www.schurter.com/pg05
1092
C14
70° C
Description
- Panel Mount:
- Screw-on from front side,
- Appliance Inlet,
- Protection class I Fuseholder for fuse-links 5 x 20 mm 2-pole, Protec-
tion class I, Pin temperature 70 °C
- Solder terminals or quick connect terminals
Approvals
- CSA License Number: 1084381
Characteristics
- The fuseholder is accessible from the equipment front
The fuse drawer "Fingergrip" can be removed by hand
- With or without rear-side insulation cover
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Material: Housing
10âA / 250âVAC; 50âHz
10âA / 250âVAC; 60âHz
> 3âkVAC between L-N
> 1.5âkVAC between L/N-PE
(1âmin/50âHz)
-25â°C to 70â°C
from front side IP 20 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Solder terminals or quick connect termi-
nals Solder terminals or quick connect
terminals straight
UL 94V-0
Appliance Inlet
Fuseholder
Power Acceptance @ Ta >
23°C
C14 acc. to IEC/EN 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10âA,
Protection Class 1
2-pole, acc. to IEC 60127-6,
for fuse-links 5 x 20âmm
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Dimensions
44 mm
44
16.50 3.20
26.90
ø 3.20
28
36
lenght of the terminal please find at the order code configuration table
19.70
5.10
37.60
Connectors
R 3.50
|
▷ |