English
Language : 

1064 Datasheet, PDF (1/4 Pages) Schurter Inc. – IEC Appliance Inlet C14 or C18 with Fuseholder 1- or 2-pole
Power entry modules without line filter
IEC Appliance Inlet C14 or C18 with Fuseholder 1- or 2-pole
www.schurter.com/pg05
1064
C14
C18
70° C
70° C
Description
- Panel Mount:
Snap-in version, from front side Appliance Inlet, Protection class
I, Fuseholder for fuse-links 5 x 20 mm
- Solder terminals or quick connect terminals
Approvals
- UL License Number: E93617
- CSA License Number: 27324
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
10 A / 250 VAC; 50 Hz
10 A / 250 VAC; 60 Hz
> 3 kVAC between L-N
> 1.5 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
from front side IP 20 acc. to IEC 60529
Suitable for appliances with protection
class 1 or 2 acc. to IEC 61140
Solder terminals or quick connect ter-
minals
Snap-in
1.0 - 1.5/2.0 - 2.5 mm
UL 94V-0
Characteristics
- The fuse drawer "Fingergrip" can be removed by hand
The fuseholder is accessible from the equipment front
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, Distributor-Stock-
Check, Accessories
Appliance Inlet
Fuseholder
Power Acceptance @ Ta >
23°C
C14 acc. to IEC/EN 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1 or 2
1 or 2 pole, acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Dimensions
32 mm
32
5
+0.2
26.9 -0
R
3
R
4.5
16.5
3
R
<3
26.7
28
Lenght of the terminal please find at the order code configuration table   
Connectors