English
Language : 

00318241 Datasheet, PDF (1/2 Pages) Schurter Inc. – Fuseholder Open Design, 5 x 20 / 6.3 x 32 mm
Fuseholder Blocks & Clips
OGD-SMD
www.schurter.com/pg02b
Fuseholder Open Design, 5 x 20 / 6.3 x 32 mm, SMD, IEC: 500 VAC, UL/CSA: 600 VAC/DC, Cover, IEC
60355-1
500 VAC · 4 W / 10 A (VDE) · 600 VAC/DC · 16 A (UL/CSA)
Description
- Fuseholder for 500 VAC applications
- Meets the new requirements of IEC 60335-1 Ed. 4.0 for appliances
in unattended use (clause 30.2.3). This includes the enhanced re-
quirements of glow wire tests acc. to IEC 60695-2-11 to -13. Order
number: 0031.8242 / 0031.8242.F1
- Fuse block accepts 5x20 or 6.3x32 fuse-links
Standards
- IEC 60127-6
- UL 4248-1 / UL 512
- CSA C22.2 no. 39
Approvals
- VDE License Number: 40008993 (250V) + 40018378 (500V)
- UL File Number: E39328
Technical Data
Fuse-Link
Mounting
Mounting
Terminal
Rated Voltage
Rated Current
Rated Power Acceptance IEC
Degree of Protection
Protection Class
Admissible Ambient Air Temp.
Climatic Category
Material: Socket
Material: Terminals
Unit Weight (Socket/Cap)
Storage Conditions
Product Marking
5 x 20 or 6.3 x 32 mm
PCB
Screw or Rivet
Solder SMT
500 VAC (VDE), 600 VAC/DC (UL/CSA)
10 A (VDE), 16 A (UL/CSA)
4 W / 10 A @ Ta 23 °C
Admissible power acceptance at hig-
her ambient temperature see derating
curves
IP 00 / IP 20
Suitable for appliances with protection
class 1 or 2 acc. to IEC 61140
-40 °C to 85 °C
40/085/21 acc. to IEC 60068-1
Thermoplastic, black, UL 94V-0
Tin-Plated Copper Alloy
3.7 g
0 °C to 60 °C, max. 70% r.h.
, Type, Voltage, Power Acc./Current
Rating, Approvals
Applications
- Equipment with three-phase supply (400 VAC)
- Industrial electronic
References
General Product Information
Packaging Details
Weblinks
Approvals, RoHS, CHINA-RoHS, e-Store, Distributor-Stock-Check,
Accessories, Product Change Notification (PCN)
Soldering Methods
Solderability
Resistance to Soldering Heat
Contact Resistance
Dielectric Strength
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category
Pollution Degree
Resistance to Vibration
Reflow (see variants)
245 °C / 3 sec acc. to IEC 60068-2-58,
Test Td
240 - 260 °C / 20 - 40 sec acc. to IPC/
JEDEC J-STD-020D
< 5 mΩ at 20 mV
> 3 kV between L-N
(50 Hz; 1 min)
> 4 kV between L-N
> 10 MΩ between L-N
(500 VDC; 1 min)
I - III acc. to IEC 60664-1
2 acc. to IEC 60664-1
acc. to IEC 60068-2-6, test Fc
Fuses