English
Language : 

00318201 Datasheet, PDF (1/3 Pages) Schurter Inc. – Fuseholder Open Design, 5 x 20 mm, THT, var. Covers, IEC 60335-1
Fuseholder Blocks & Clips
Fuseholder Open Design, 5 x 20 mm, THT, var. Covers, IEC 60335-1
www.schurter.com/pg02b
OGN
250 VAC · 4 W / 10 A (VDE) · 500 VAC/DC · 10 A (UL/CSA)
Description
- Meets the new requirements of IEC 60335-1 Ed. 4.0 for appliances
in unattended use (clause 30.2.3). This includes the enhanced re-
quirements of glow wire tests acc. to IEC 60695-2-11 to -13. Order
number: 0031.82x1.15
- Low profile fuse block with insulation walls
- Screw or rivet fastening
Standards
- IEC 60127-6
- UL 4248-1 / UL 512
- CSA C22.2 no. 39
Approvals
- VDE License Number: 40001042
- UL File Number: E39328
Applications
- Industrial electronic
- Household appliances
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, e-Store, Distributor-Stock-Check,
Accessories, Product Change Notification (PCN)
Technical Data
Fuse-Link
Mounting
Mounting
Terminal
Rated Voltage
Rated Current
Rated Power Acceptance IEC
Degree of Protection
Protection Class
Admissible Ambient Air Temp.
Climatic Category
Material: Socket
Material: Terminals
Unit Weight (Socket/Cap)
Storage Conditions
Product Marking
5 x 20 mm
PCB
Screw or Rivet
Solder THT
250 VAC (VDE), 500 VAC/DC (UL/CSA)
10 A (VDE), 10 A (UL/CSA)
4 W / 10 A @ Ta 23 °C
2.5 W / 10 A with transparant cover, see
derating curves
IP 00 / IP 20
Suitable for appliances with protection
class 1 or 2 acc. to IEC 61140
-40 °C to 85 °C
40/085/21 acc. to IEC 60068-1
see variants
Tin-Plated Copper Alloy
1.7 g
0 °C to 60 °C, max. 70% r.h.
, Type, Voltage, Power Acc./Current
Rating, Approvals
Soldering Methods
Solderability
Resistance to Soldering Heat
Contact Resistance
Dielectric Strength
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category
Pollution Degree
Resistance to Vibration
Wave
235 °C / 2 sec acc. to IEC 60068-2-20,
Test Ta, method 1
260 °C / 10 sec acc. to IEC 60068-2-20,
Test Tb, method 1A
< 5 mΩ at 20 mV
> 3 kV between L-N
(50 Hz; 1 min)
> 4 kV between L-N
> 10 MΩ between L-N
(500 VDC; 1 min)
I - III acc. to IEC 60664-1
1 - 3 acc. to IEC 60664-1
acc. to IEC 60068-2-6, test Fc
Fuses